Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
Search Results "Grab Bar Clearance"
-
11B-604.8.1.2 Doors
- Hill-Rom Sabina® II Mobile Lift
- Pilot Rock WXT and WXTH Picnic Table Using Aluminum
- Pilot Rock WUT and WUTH Picnic Table - Using Aluminum
- Bobrick ConturaSeries Surface-Mounted Seat-Cover Dispenser B-4221
- Bobrick Recessed Paper Towel Dispenser B-318
-
902.1 General
Dining surfaces include, but are not limited to, bars, tables, lunch counters, and booths....
-
F204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
-
204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
-
4.1.6(3)(c)(iii)
For example, an elevator of 47 in by 69 in (1195 mm by 1755 mm) with a door opening on the narrow dimension, could accommodate the standard wheelchair clearances shown in Figure 4....
-
4.2.6* Side Reach
If the side reach is over an obstruction, the reach and clearances shall be as shown in Fig 6(c)....
-
4.18.3 Clear Floor Space
Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29 in (735 mm) clearance between them....
-
4.1.6(4)(d)
(i) Where existing elements prohibit strict compliance with the clearance requirements of 4.13.5, a projection of 5/8 in (16 mm) maximum will be permitted for the latch side door stop....
-
4.2.5 FORWARD REACH
If the high forward reach is over an obstruction, reach and clearances shall be as shown in Fig. 5(b). Figure 5 Forward Reach...
-
4.18.3 CLEAR FLOOR SPACE
Urinal shields that do not extend beyond the front edge of the urinal rim may be provided with 29 in (735 mm) clearance between them....
-
§ 38.159(a)(1) General
., lift or ramp) complying with paragraph (b) or (c) of this section and sufficient clearances to permit a wheelchair or other mobility aid user to reach a securement location....
-
Definitions of residential facilities and transient lodging
Similarly, grab bars and shower seats would not have to be installed at the time of construction provided that reinforcement has been installed in walls and located so as to permit their...
-
213 Toilet Facilities and Bathing Facilities
4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3, at least one stall 36 in (915 mm) wide with an outward swinging, self- closing door and parallel grab...
-
Definitions of residential facilities and transient lodging. (Section-by-Section Analysis)
Similarly, grab bars and shower seats would not have to be installed at the time of construction provided that reinforcement has been installed in walls and located so as to permit their...
-
4.3.9 Doorway Design
The lack of differences between the findings for the passage task on the pull sides of Doors 1, 800 mm (31.5 in.) latch clearance, and Door 2, 406 mm (16 in.) latch clearance, demonstrate...
-
11B-704.5 TTY shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (152 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....
-
204.1 General
Within play areas, protruding objects on circulation paths shall not be required to comply with 307 provided that ground level accessible routes provide vertical clearance in compliance...
-
704.5 TTY Shelf
The shelf shall be capable of accommodating a TTY and shall have 6 inches (150 mm) minimum vertical clearance above the area where the TTY is to be placed....