Exception: Nonpublic aisles serving less than 50 people and not required to be accessible by Chapter 11B (see Section 11B-403) need not exceed 28 inches (711 mm) in width....
Search Results "Exception"
-
1018.5 Aisles in other than assembly spaces and Groups B and M
-
233.4.2
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted....
-
502.2 Vehicle Spaces
EXCEPTION: Van parking spaces shall be permitted to be 96 inches (2440 mm) wide minimum where the access aisle is 96 inches (2440 mm) wide minimum....
-
1009.2.1 Pool Lift Location
EXCEPTIONS: 1. Where the entire pool depth is greater than 48 inches (1220 mm), compliance with 1009.2.1 shall not be required. 2....
-
407.4.8.2.1 Signal Type
EXCEPTION: For elevators other than destination-oriented elevators that have a rated speed of 200 feet per minute (1 m/s) or less, a non-verbal audible signal with a frequency of 1500 Hz...
-
608.4 Seats
EXCEPTION: In residential dwelling units, seats shall not be required in transfer type shower compartments provided that reinforcement has been installed in walls so as to permit the installation...
-
232.5.1 Cubicles and Counters
EXCEPTION: The inmate or detainee side of cubicles or counters at non-contact visiting areas not serving holding cells or housing cells required to comply with 232 shall not be required...
-
409.3.1 Power Operation
EXCEPTION: In elevator cars with more than one opening, hoistway doors and gates shall be permitted to be of the manual-open, self-close type....
-
604.8.2.2 Doors
Toilet compartment doors, including door hardware, shall comply with 404, except that if the approach is to the latch side of the compartment door, clearance between the door side of the...
-
Wheelchair Space or Transfer Seat or Transfer Device
Sections 234.3 and 1002.4 - 1002.6 of the 2010 Standards provide that each new and altered amusement ride, except for mobile/portable rides and a few additional excepted rides, will be required...
-
11B-408.4.1 Car dimensions and doors
Exceptions: 1. ...
-
F221.2.3.2 Vertical Dispersion
[ECTCR UFAS 4.33.3, 4.1.6(4)(f)(i)] EXCEPTIONS: 1....
-
R302.3.2 Shared Use Paths
As proposed in the NPRM, R302.3 would require pedestrian access routes to be 4 feet wide minimum, except R302.3.1 would require pedestrian access routes within medians and pedestrian refuge...
-
F208.2 Minimum Number
Parking spaces complying with 502 shall be provided in accordance with Table F208.2 except as required by F208.2.1, F208.2.2, and F208.2.3....
-
Background
to a 2013 CBC requirement for public accommodations and commercial facilities can be found by deleting the "11B-" prefix to obtain the ADAS reference number, although there are numerous exceptions...
-
10.3.2(4)
EXCEPTION 1: Existing vehicles retrofitted to meet the requirements of 49 CFR 37.93 (one-car-per-train rule) shall be coordinated with the platform such that, for at least one door, the...
-
1010.1.7 Thresholds
Exceptions: 1....
-
11B-215.1 General
Exception: In existing facilities, visible alarms for fire alarm systems shall not be required except where an existing fire alarm system is upgraded or replaced, or a new fire alarm system...
-
Track Crossing
An exception preserves the permitted 2 ½ inch gap for wheel flanges....
-
11B-217.5 Shelves for portable TTYs
Exceptions: 1. ...
-
§382.133(b)
(b) Except for foreign carriers conducting operations of a nature equivalent to on-demand air taxi operations by a U.S. carrier, as a foreign carrier conducting passenger service you must...
-
11B-216.5.1 Parking spaces
Exceptions: 1. Reserved. [2010 ADAS] 1. ...
-
404.2.11 Vision Lights
[ECTCR UFAS 4.13.1] EXCEPTION: Vision lights with the lowest part more than 66 inches (1675 mm) from the finish floor or ground shall not be required to comply with 404.2.11....
-
Pool Lifts
If the entire pool is deeper than 48 inches, an exception allows operators to use a pool lift in any location as an accessible means of entry. ...