In such a design, curbs or barriers are not required....
Search Results "Curb Ramp Slope"
Commonly Searched Documents
-
1005.3 Edge Protection
-
11B-1005.1 Accessible routes
length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
-
Gangways
Gangways A gangway is a variable-sloped pedestrian walkway linking a fixed structure or land with a floating structure....
-
1009.4.1 Clear Deck Space
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Thresholds at Doorways [4.13.8]
Thresholds above ¼ inch must be beveled with a slope no greater than 1:2....
-
2) Where the Standard says "Changes in level are not permitted"
such as 304.2 for turning spaces: Here the standard is followed by an unenforceable advisory that says, "As used in this section, the phrase ‘changes in level’ refers to surfaces with slopes...
-
4.33.3* PLACEMENT OF WHEELCHAIR LOCATIONS
EXCEPTION: Accessible viewing positions may be clustered for bleachers, balconies, and other areas having sight lines that require slopes of greater than 5 percent....
-
11B-1005.1 Accessible routes
length of the gangway or series of gangways serving as part of a required accessible route is 30 feet (9144 mm) minimum, gangways shall not be required to comply with Section 11B-405.2 _|Slope...
-
Re: Angled Parking
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Handrails, Grab Bars, and Tub and Shower Seats [4.26]
Handrails, Grab Bars, and Tub and Shower Seats [4.26] ADAAG 4.26 provides technical requirements for: handrails at ramps [4.8] and stairs [4.9] grab bars at water closets...
-
11B-810.5.3 Platform and vehicle floor coordination
operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192 or 49 CFR part 38, mini-high platforms, car-borne or platform-mounted lifts, ramps...
-
What materials may satisfy ADAAG requirements?
there is a choice between flooring materials otherwise suitable for a particular application, we recommend choosing the material with the higher coefficient of friction, particularly for ramps...
-
11B-235.2.1 Dispersion
The term "boat slip" is intended to cover any pier area other than launch ramp boarding piers where recreational boats are moored for purposes of berthing, embarking, or disembarking....
-
1009.1 Accessible means of egress required
In assembly areas with ramped aisles or stepped aisles, one accessible means of egress is permitted where the common path of egress travel is accessible and meets the requirements in Section...
-
Issue 20: Why should we embark on a new guideline?
So for example, and I think I used this example and I apologize, yesterday, we say that for people who use wheelchairs, you design a ramp....
- Harmar CPL800H-1400H Hydraulic CPL with Modular Tower
-
R309.5.1 Location
Locating parking meters at the head or foot of the parking space permits deployment of a van side-lift or ramp or the vehicle occupant to transfer to a wheelchair or scooter....
-
11B-1005.3 Edge protection
In such a design, curbs or barriers are not required....
-
308.3.1 Unobstructed
Operable parts of fuel dispensers shall be permitted to be 54 inches (1370 mm) maximum measured from the surface of the vehicular way where fuel dispensers are installed on existing curbs...
-
25. Need for Return Trip Assistance
For example, a dialysis patient may have no problem waiting at the curb for a ride to go to the dialysis center, but may well require assistance to the door on his or her return trip because...
-
11B-1005.3 Edge protection
In such a design, curbs or barriers are not required....
-
25. Need for Return Trip Assistance
For example, a dialysis patient may have no problem waiting at the curb for a ride to go to the dialysis center, but may well require assistance to the door on his or her return trip because...
-
11B-1005.3 Edge protection
In such a design, curbs or barriers are not required. ◼...
-
F. Swimming Pool Entrance and Deck
(4) The swimming pool deck ramp, which has an intermediate ramp landing area that is 37 ½ inches long, rather than the required 60 inches, will be supplemented by a platform lift at...