Vehicle spaces serving ambulatory EVCS shall be 120 inches (3048 mm) wide minimum and shall not be required to have an adjacent access aisle....
Search Results "Minimum Dimension"
-
11B-812.6.3 Ambulatory
-
11B-705.1.2.6 Reflecting pools
When detectable warnings are provided at reflecting pools, it shall be 24 inches (610 mm) minimum and 36 inches (914 mm) maximum in width....
-
11B-505.2.1 Orientation
The orientation of at least one handrail shall be in the direction of the stair run, perpendicular to the direction of the stair nosing, and shall not reduce the minimum required width of...
-
11B-902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (762 mm) maximum above the finish floor or ground....
-
11B-904.5.2 Tray slides
The tops of tray slides shall be 28 inches (711 mm) minimum and 34 inches (864 mm) maximum above the finish floor or ground....
-
11B-407.4.7.1.5 Button spacing
A minimum clear space of 3/8 inch (9.5 mm) or other suitable means of separation shall be provided between rows of control buttons....
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
233.4.1
233.4.1 In sleeping rooms with more than 25 beds, a minimum of 5% of the beds shall have clear floor space complying with section 806.2.3....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
224.3 Beds
In guest rooms having more than 25 beds, 5 percent minimum of the beds shall have clear floor space complying with 806.2.3....
-
902.4.2 Height
The tops of tables and counters shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the finish floor or ground....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
1007.3.2 Golf Club Reach Range Area
All areas within holes where golf balls rest shall be within 36 inches (915 mm) maximum of a clear floor or ground space 36 inches (915 mm) wide minimum and 48 inches (1220 mm) long minimum...
-
Grab Bars
If only one bar is provided, the clearance must be a minimum of 24 inches on each side of the bar....
-
11B-411.2.1.2.1 Keypads
The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
11B-503.5 Vertical clearance
and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide a vertical clearance of 114 inches (2896 mm) minimum...
-
10.2.1(1)
(1) Where new bus stop pads are constructed at bus stops, bays or other areas where a lift or ramp is to be deployed, they shall have a firm, stable surface; a minimum clear length of 96...
-
1018.4 Clear Width
This section requires the clear width of beach access routes to be 60 inches minimum to enable individuals who use wheeled mobility devices to pass beach visitors traveling in the opposite...
-
604.3.2 Overlap
EXCEPTION: In residential dwelling units, a lavatory complying with 606 shall be permitted on the rear wall 18 inches (455 mm) minimum from the water closet centerline where the clearance...
-
Must elevator doors remain open for 20 seconds?
LULA swing doors, private residence elevator doors, and platform lift gates and doors must remain open for 20 seconds minimum....
-
Clearances between a handrail and wall surface: 2012 NFPA 101 vs. 2010 ADA
ETA Interpretation/Opinion: Clearances between a handrail and wall surface: The 2010 ADA now requires the 1.5” as a minimum. 2012 NFPA 101 Life Safety Code will be requiring 2.25” minimum...
-
11B-411.2.1.2.1 Keypads
The dot shall have a base diameter of 0.118 inch (3 mm) minimum and 0.120 inch (3.05 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
11B-307.4 Vertical clearance
Vertical clearance shall be 80 inches (2032 mm) high minimum. Guardrails or other barriers shall be provided where the vertical clearance is less than 80 inches (2032 mm) high....
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....