Exceptions: 1....
Search Results "Exception"
Commonly Searched Documents
-
11B-212.3 Sinks
-
11B-212.3 Sinks
Exceptions: Mop, service or scullery sinks shall not be required to comply with Section 11B-212.3....
-
Caution regarding minimum Aisle Widths for aisles that serve "elements on both sides"
As a heads up, care should be taken in applying the technical aspects of 11B-403.5.1, Exception 4 re: minimum aisle width in California....
-
F216.1 General
EXCEPTIONS: 1....
-
1630.2(e)(1)
industry affecting commerce who has 15 or more employees for each working day in each of 20 or more calendar weeks in the current or preceding calendar year, and any agent of such person, except...
-
11B-1009.3.2 Submerged depth
Exception: In wading pools, the sloped entry and landings, if provided, shall extend to the deepest part of the wading pool....
-
221.8 Temporary Platforms or Other Movable Structures
Wheelchair spaces and companion seats shall not be located on (or obstructed by) temporary platforms or other movable structures, except that when an entire seating section is placed on...
-
3.6 Who Is Entitled to a Reasonable Accommodation?
qualified individual with a disability" (meets all prerequisites for performing the essential functions of a job [being considered for a job or enjoying equal benefits and privileges of a job] except...
-
604.2 Location
The centerline of the water closet shall be 16 inches (405 mm) minimum to 18 inches (455 mm) maximum from the side wall or partition, except that the water closet shall be 17 inches (430...
-
11B-902.1 General
Exception: Dining surfaces and work surfaces for children’s use shall be permitted to comply with Section 11B-902.4. [2010 ADAS] Advisory 902.1 General. ...
-
Assistive Listening System Signage
In the final rule, the requirement has been revised to require signs for assistive listening systems at each assembly area required to provide an assistive listening system, but an exception...
-
11B-233.3.1 Minimum number: new construction
Exception: Where facilities contain 15 or fewer residential dwelling units, the requirements of Sections 11B-233.3.1.1 and 11B-233.3.1.3 _|Residential Dwelling Units with Communication...
-
904.4.1 Parallel Approach
[ECTCR UFAS 7.2] EXCEPTION: Where the provided counter surface is less than 36 inches (915 mm) long, the entire counter surface shall be 36 inches (915 mm) high maximum above the finish...
-
216.1 General
EXCEPTIONS: 1....
-
406.4 Landings
EXCEPTION: In alterations, where there is no landing at the top of curb ramps, curb ramp flares shall be provided and shall not be steeper than 1:12....
-
217.2 Wheelchair Accessible Telephones
EXCEPTION: Drive-up only public telephones shall not be required to comply with 217.2....
-
Animal Containment Areas
These areas must comply with all ADAAG requirements, except the requirements that surfaces be stable, firm, and slip resistant and the restrictions on changes in level since some surfaces...
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
1011.7 Outdoor Rinsing Showers
EXCEPTION: Where vandalism is a consideration, a fixed shower head located at 48 inches (1220 mm) above the ground shall be permitted in place of a hand-held shower spray unit....
-
810.6.2 Routes and Destinations
EXCEPTION: Where sign space is limited, characters shall not be required to exceed 3 inches (75 mm). Advisory 810.6.2 Routes and Destinations....
-
703.3.2 Position
EXCEPTION: Braille provided on elevator car controls shall be separated 3/16 inch (4.8 mm) minimum and shall be located either directly below or adjacent to the corresponding raised characters...
-
904.4 Sales and Service Counters
EXCEPTION: In alterations, when the provision of a counter complying with 904.4 would result in a reduction of the number of existing counters at work stations or a reduction of the number...
-
206.8 Security Barriers
EXCEPTION: Where security barriers incorporate elements that cannot comply with these requirements such as certain metal detectors, fluoroscopes, or other similar devices, the accessible...
-
R302.6 Cross Slope
Except as provided in R302.6.1 and R302.6.2, the cross slope of pedestrian access routes shall be 2 percent maximum. Advisory R302.6 Cross Slope....