Buildings connected by pedestrian walkways or tunnels shall be considered to be separate structures....
Search Results "CBC: California Building Code"
-
3104.2 Separate structures
-
Ground Floor
In the final Guidelines, "ground floor" is defined as follows: "Ground floor" means a floor of a building with a building entrance on an accessible route....
-
11B-608.7 Thresholds
ETA Editor's Note The 2013 CBC requirement for thresholds at accessible showers is more restrictive than 2010 ADAS....
-
11B-213.3.6 Bathing facilities
The 2013 CBC scoping requirements are more stringent, since they address not only the quantity of accessible showers, but also their orientation....
-
11B-404.2.11 Vision lights
ETA Editor's Note The vision light requirement of 2013 CBC 11B-404.2.11 is new, derived from 2010 ADAS 404.2.11. ...
-
11B-502.5 Vertical clearance
ETA Editor's Note 2013 CBC requires 98 inches minimum vertical clearance at all accessible parking spaces, not solely van accessible parking spaces. ...
-
11B-608.4 Seats
ETA Editor's Note Unlike 2010 ADAS, 2013 CBC requires a folding seat at all accessible showers, unless the Exception above is applicable....
-
11B-608.4 Seats
ETA Editor's Note Unlike 2010 ADAS, CBC requires a folding seat at all accessible showers, unless the Exception above is applicable....
-
11B-608.7 Thresholds
ETA Editor's Note The CBC requirement for thresholds at accessible showers is more restrictive than 2010 ADAS....
-
11B-502.5 Vertical clearance
ETA Editor's Note CBC requires 98 inches minimum vertical clearance at all accessible parking spaces, not solely van accessible parking spaces. ...
-
11B-213.3.6 Bathing facilities
The CBC scoping requirements are more stringent, since they address not only the quantity of accessible showers, but also their orientation. ...
-
11B-608.4 Seats
ETA Editor's Note Unlike 2010 ADA Standards, CBC requires a folding seat at all accessible showers, unless the Exception above is applicable....
-
11B-705.1.2.2.2.1 One entrance/exit point
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
-
11B-705.1.2.2.2.1 One entrance/exit point
Existing parallel curb ramps with detectable warnings in compliance with the code requirements in effect at the time of installation shall not be required to provide a minimum 36 inches...
- Moen M–Dura Chrome Two-Handle Utility Faucet 8119
- Seton Optima Men Restroom Sign
- Moen M–Dura Chrome Two-Handle Utility Faucet 8121
- Otis Gen2 Elevator
-
F230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with 708....
-
3104.2 Separate structures
Buildings connected by pedestrian walkways or tunnels shall be considered to be separate structures. Exceptions: 1. ... 2....
-
230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with 708....
-
11B-206.7 Platform lifts
Platform lifts shall be permitted as a component of an accessible route in an existing building or facility....
-
11B-206.7 Platform lifts
Platform lifts shall be permitted as a component of an accessible route in an existing building or facility....
-
11B-213.3.1 Toilet compartments
SECTION TITLE NOTES 11B-213.3.1 Toilet compartments Corrects drafting error in prior code...