They must be tactile and located at the latch side of the door as prescribed by CBC Section 11B-703.4....
Search Results "Fire Door"
Commonly Searched Documents
-
1023.9 Stairway identification signs
-
Attachment I: Program Access in Existing Facilities
Attachment I: Program Access in Existing Facilities
-
2. b. i. Clear door openings
Clear door openings: Door openings should provide a clear width of 32 inches (815 mm) minimum....
-
408.4.1 Car Dimensions and Doors
Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (815 mm) minimum clear width. EXCEPTIONS: 1....
-
1010.2 Door operations
...
-
408.4.1 Car Dimensions and Doors
Car doors shall be positioned at the narrow ends of cars and shall provide 32 inches (815 mm) minimum clear width. EXCEPTIONS: 1....
-
4.29.3* TACTILE WARNINGS ON DOORS TO HAZARDOUS AREAS
Doors that lead to areas that might prove dangerous to a blind person (for example, doors to loading platforms, boiler rooms, stages, and the like) shall be made identifiable to the touch...
-
2. b. ii. Accessible Door Hardware
Door handles: Inaccessible door hardware (Figure 14 below) can prevent access to medical offices....
- Allegion aptiQ SM10 Smart Mini-Mullion Reader
- Allegion aptiQ Multi-Technology Single Gang Reader
- Allegion aptiQ MTMS15 Multi-Technology Magnetic Stripe Reader
- Allegion XceedID® PR10 Proximity Mini-Mullion Reader
-
When door vision lights are limited to 100 square inches by the fire code, is compliance with the specified maximum height of 43” to the bottom edge still required?
The Standards do not exempt such doors from the requirement for vision lights (§404.2.11)....
- Inclusion Solutions BigBell™ Flex Alert System
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door....
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door....
-
11B-804.6.5.2 Bottom-hinged door ovens
Bottom-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to one side of the door....
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
11B-804.6.5.1 Side-hinged door ovens
Side-hinged door ovens shall have the work surface required by Section 11B-804.3 positioned adjacent to the latch side of the oven door....
-
Plumbing/Restrooms
PLUMBING/RESTROOMS Turning space within the room 11B-603 Door swing not in clear floor space of any fixture (except...
-
702 Fire Alarm Systems
[See subsections ...]
-
VII. Fire Alarm System...
[See subsections ...]
-
Priority 2: Access to Goods & Services