Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of...
Search Results "Emergency Transportable Housing Unit"
-
1132A.9 Smooth surface
-
11B-809.10.3 Powder rooms
Powder rooms shall be designed to comply with Sections 11B-809.7, 11B-809.8, 11B-809.10.5.2, 11B-809.10.6.4, 11B-809.10.7.3, and 11B-809.12. When the powder room is the only toilet...
-
1132A.9 Smooth surface
Swinging door or gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of...
-
II. Cost-disproportionality Is Only a Factor Under Certain Circumstances
Reg. 35544, 35581 (July 26, 1991) (Title II of the ADA regarding public services and public transportation is identical in pertinent language to Title III of the ADA) (“Costs are to be considered...
-
1133A.4, Item 3
Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components....
-
1133A.4, Item 3
Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components....
-
The Roles of the Access Board and the Department of Justice
be individuals with disabilities, and the heads of twelve federal departments and agencies specified by statute, including the heads of the Department of Justice and the Department of Transportation...
-
Alterations to Residential Facilities
Section 4.1.6 of the UFAS requires federal, state, and local government housing to comply with the general requirements for alterations to facilities....
-
409.1 General
Private residence elevators that are provided within a residential dwelling unit required to provide mobility features complying with 809.2 through 809.4 shall comply with 409 and with ASME...
-
11B-233.3.1.2.2 Non-elevator buildings
Ground floor residential dwelling units in non-elevator buildings shall be adaptable....
-
Accessible Cells in Detention and Correctional Facilities (Section-by-Section Analysis)
Other complaints allege that inmates with mobility disabilities are housed in medical units or infirmaries separate from the general population simply because there are no accessible cells...
-
409.1 General
Private residence elevators that are provided within a residential dwelling unit required to provide mobility features complying with 809.2 through 809.4 shall comply with 409 and with ASME...
-
11B-604.4 Seats
In residential dwelling units, the height of water closets shall be permitted to be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum above the finish floor measured to the top of...
-
11B-604.4 Seats
In residential dwelling units, the height of water closets shall be permitted to be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum above the finish floor measured to the top of...
-
11B-604.4 Seats
In residential dwelling units, the height of water closets shall be permitted to be 15 inches (381 mm) minimum and 19 inches (483 mm) maximum above the finish floor measured to the top of...
-
1007.7 Signage
At exits and elevators serving a required accessible space but not providing an approved accessible means of egress, signage shall be installed indicating the location of accessible...
-
1003.2.13.6 Signage
At exits and elevators serving a required accessible space but not providing an approved accessible means of egress, signage shall be installed indicating the location of accessible...
-
K5
K5. If the operating controls are set back 10 to 24 inches from the front edge of the counter or table are they no higher than 46 inches above the floor? [ADA Standards §...
-
207 Accessible Means of Egress
207 Accessible Means of Egress
-
608.5.1 Transfer Type Shower Compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1220 mm...
-
F244.5.3 Routes to Adjacent Recreation Facilities
Where a circulation path connects camping facilities and adjacent recreation facilities, at least one outdoor recreation access route shall connect camping units with mobility features to...
-
11B-608.5.1 Transfer type shower compartments
In transfer type shower compartments, the controls, faucets, and shower spray unit shall be installed on the side wall opposite the seat 38 inches (965 mm) minimum and 48 inches (1219 mm...
-
11B-809.7 Accessible routes
The accessible route shall pass through the primary entry door, through all rooms within the dwelling unit and exterior decks and balconies....
-
Air Carrier Access Act Technical Assistance Manual (2005)
What Airline Employees, Airline Contractors, and Air Travelers with Disabilities Need to Know About Access to Air Travel for Persons with Disabilities A Guide to the Air Carrier...