PHYSICAL PROVISIONS Usable without simultaneous actions Provide at least one mode that does not require simultaneous actions....
Search Results "One Step Entry"
Commonly Searched Documents
-
PHYSICAL PROVISIONS
-
5.3.2.2 Transfer Sides Recommendation for Imaging Equipment
The Committee recommends that imaging equipment provide transfer surfaces on at least one long side of the table....
-
M301.2.3 Transfer Surface Transfer Sides
The option to transfer will be required only on one long side of the patient scanning/imaging table and not at the “foot” or “head” end of such surfaces....
-
5. What will happen after I ask for a reasonable accommodation?
If a reasonable accommodation would help you to do your job, your employer must give you one unless the accommodation involves significant difficulty or expense....
-
7.2.2.1 Determining Impracticability
The use of General Exception 2 is reasonable where one or more conditions for an exemption in section 7.1 and at least one of the following limiting factors exist: Limiting Factor 1. ...
-
Error/Omission: Toilet rooms with 6 or more toilet stalls lack a 36" wide "ambulatory" toilet stall.
If toilet stalls are provided, then at least one shall be a standard toilet stall complying with 4.17; where 6 or more stalls are provided, in addition to the stall complying with 4.17.3...
-
11B-231.4.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....
-
F202.2.1 Accessible Route
At least one accessible route shall be provided within the site from accessible parking spaces and accessible passenger loading zones; public streets and sidewalks; and public transportation...
-
Resort Condominium
resort condominium is any unit or group of units in a condominium, cooperative, or time-share plan which is rented more than three times a calendar year for periods of less than 30 days or one...
-
D2
Does at least one door or one side of a double leaf-door provide at least 32 inches clear passage width when the door is open 90 degrees?...
-
D. Clear Floor Space
If there is a vestibule without fully automatic doors, is there a 30"x48" clear floor space where one can be outside the swing of a hinged door (i.e.: for out-swinging doors, at least 7'...
-
§ 36.406(d)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities, shall provide at least one roll in shower with a seat that complies with the relevant...
-
10.4.1(4)
(4) Where public pay telephones are provided, and at least one is at an interior location, a public text telephone shall be provided in compliance with 4.31.9....
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
R212.6 Benches
At least 50 percent, but no less than one, of benches at each location shall provide clear space complying with R404 adjacent to the bench....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
1011.7 Outdoor Rinsing Showers
This section requires outdoor rinsing showers to provide at least one hand-held shower spray unit with a hose 59 inches long minimum....
-
222 Dressing, Fitting, and Locker Rooms
Where coat hooks or shelves are provided in dressing, fitting or locker rooms without individual compartments, at least one of each type shall comply with 803.5....
-
§100.201 Dwelling unit
Dwelling unit means a single unit of residence for a family or one or more persons....
-
4.22.3 CLEAR FLOOR SPACE
EXCEPTION: In toilet rooms with only one water closet and one lavatory, a clear floor space of 30 in by 60 in (815 mm by 1525 mm) may be used in lieu of the unobstructed turning space....
-
4.1.1(6)
EXCEPTION: These provisions are not mandatory for single user portable toilet or bathing units clustered at a single location; however, at least one toilet unit complying with 4.22 or one...
-
Are accessible spaces required on all levels of a multi-level parking structure?
If a parking facility has entrances and exits on one level only, standard and van accessible spaces are required on that level so that they are on the shortest accessible route to the entrance...
-
§ 35.151(e)(2)
(2) Facilities with more than 50 beds covered by this section that provide common use bathing facilities shall provide at least one roll-in shower with a seat that complies with the relevant...
-
11B-231.4.1 Cubicles and counters
At least 5 percent, but no fewer than one, of cubicles shall comply with Section 11B-902 on both the visitor and detainee sides....