Overhead Track Lifts Overhead track lifts include ceiling mounted lifts and lifts mounted on a frame supported from the floor....
Search Results "Floor Destination"
Commonly Searched Documents
-
Overhead Track Lifts
-
F. Stairs
Stairs - Are there floors connected only by stairs, not an elevator or ramp? [ADA Stds. 4.1.3(4)] If yes, then......
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
5a.
Are the elevator call buttons mounted in an accessible location with the centerlines at 42 inches above the floor? [ADA Stds 4.10.3] Yes _____ No _____...
-
4.32.4* Height of Tables or Counters
The tops of accessible tables and counters shall be from 28 in to 34 in (710 mm to 865 mm) above the finish floor or ground....
-
5d.
Are raised letters and Braille characters used to identify each floor button and each control? [ADA Stds 4.10.12] Yes _____ No _____...
-
Height
The models were installed at 39 inches above finished floor to the base....
-
5.1.4 Turning Space
Where the camp shelter floor is not elevated above the trail or ORAR, a turning space complying with ABAAS section 304.3 shall be provided....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
1133A.5 Lower shelving
Lower shelving and/or drawer space shall be provided in the kitchen at a height of no more than 48 inches (1219 mm) above the floor....
-
810 Transportation Facilities
This revision does not substantively change the requirements for the coordination of platforms and vehicle floors. Comment....
-
11B-604.7 Dispensers and disposal units
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
Viewing Areas
Because overlooks and viewing areas are destination points, they must be accessible so all visitors can enjoy the viewing opportunities....
-
Transfer Surface Height (M301.2.1 and M302.2.1)
M301.2.1 and M302.2.1 would require the height of the transfer surface during patient transfer to be 17 inches minimum and 19 inches maximum measured from the floor to the top of the transfer...
-
1.14 Riser
1.14 "Riser" shall mean and refer to an elevated tier (usually six to eighteen inches) in an auditorium on which seats are affixed to the auditorium floor....
-
4. Toilet seat height
Toilet seat height: The toilet seat needs to be from 17 to 19 inches above the floor to permit transfers to and from wheelchairs....
-
Question 20
Is the required floor and wall space inside public restrooms and fitting rooms blocked by obstacles such as trash cans, chairs, or shelving?...
-
J3
Is the top of the spout no higher than 36 inches above the floor and at the front of the fountain or water cooler? [ADA Standards § 4.15.2] Yes No...
-
I. Toilet Seat
Is the toilet seat at each accessible toilet between 17"-19" above the floor? [ADA Stds. 4.16.3] Yes __ No __ N/A __ Comments: ___________________________________________...
-
e-vii
Is the elevator equipped with audible tones or bells or verbal annunciators that announce each floor as it is passed? [ADA Standards § 4.10.13] Yes No...
-
4.15.2* Spout Height
Spouts shall be no higher than 36 in (915 mm), measured from the floor or ground surfaces to the spout outlet (see Fig. 27(a))....
-
5.1.4 Turning Space
Where the camp shelter floor is not elevated above the trail or ORAR, as applicable, a turning space complying with ABAAS section 304.3 shall be provided....
-
4.19.6* MIRRORS