Upon presentation of security credential, the destination floor shall be confirmed by verbal announcement and on the display screen....
Search Results "Floor Button"
Commonly Searched Documents
-
11B-411.2.1.7.3 Assignment by security credential
-
11B-604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (356 mm) minimum and 19 inches (483 mm) maximum above the finish floor....
-
11B-605.4 Flush controls
Hand operated flush controls shall comply with Section 11B-309 except that the flush control shall be mounted at a maximum height of 44 inches (1118 mm) above the finish floor. ...
-
11B-804.3 Kitchen work surface
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, at least one 30 inches (762 mm...
- HumanWare Trekker Breeze+ Handheld Talking GPS
-
11B-603.4 Coat hooks, shelves and medicine cabinets
Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
4.4.1* General
Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100...
-
11B-704.2.1.2 Forward approach
Where a forward approach is provided at a telephone within an enclosure, the counter may extend beyond the face of the telephone 20 inches (508 mm) into the required clear floor or ground...
- Willoughby Industries ADA Cabinet Shower US-FA-HC
- BEA Inc. LZR Microscan Installation Video
-
11B-611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (914 mm) maximum above the finish floor....
-
611.4 Height
Top loading machines shall have the door to the laundry compartment located 36 inches (915 mm) maximum above the finish floor....
-
410 Platform Lifts
Section 410 provides requirements for platform lifts and addresses floor surfaces, clear floor space, operable parts, and doors and gates....
-
Main Lobby
The 40 1/2" height of the main ticket counter exceeds the maximum allowable height of 36" above the finished floor. See Standards § 7.2(1). j....
-
Accessible Route
Interior accessible routes may include corridors, floors, ramps, elevators, lifts, and clear floor space at fixtures....
-
Scoping [4.1.3(10)]
Instead it requires access based on the number provided on each floor so that half (50%) are accessible to people who use wheelchairs....
-
Dispersion
For example, if a floor is occupied by separate tenancies, both types of units should be dispersed to serve occupants of each tenancy....
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
-
III-7.5140 Drinking fountains
Where there is only one drinking fountain on a floor, it must be accessible both to individuals who use wheelchairs and to those who have difficulty bending or stooping (for example, by...
- Takeform Fusion Signage Interior Stairwell Type N
-
206.2.3 Multi-Story Buildings and Facilities
However, if the laundry room on the first floor is restricted to use by residents on the first floor, and the second floor laundry room is for use by occupants of the second floor, then...
-
1134A.6, Item 4
Grab bar reinforcement shall be installed continuous in the walls of showers 32 inches to 38 inches (813 mm to 965 mm) above the floor....
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
