buildings equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 or 903.3.1.2, the elevator shall not be required on floors provided with a ramp...
Search Results "Curb Ramp Top Landing"
Commonly Searched Documents
-
1009.2.1 Elevators required
-
Acknowledgments
available on the Internet at: http://www.fs.fed.us/t-d/pubs/htmlpubs/htm06232340/drawings/ (Username: t-d, Password: t-d) These drawings can be viewed by Forest Service and Bureau of Land...
-
Appalachian Trail Conservancy's "Backcountry Sanitation Manual"
Resolving problems of backcountry sanitation is a continuous challenge for trail clubs and land managers....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
-
1132A.5.1 General
The floor or landing on the dwelling unit side of the primary entry door and any required exit door shall have a minimum length of not less than 44 inches (1118 mm)....
- Walk-A-Sured Roll-On Anti-Slip Safety Coating System
- Walk-A-Sured Clear Anti-Slip Safety Coating System
-
For more information about the ADA
ADA Website www.ADA.gov To receive e-mail notifications when new ADA information is available, visit the ADA Website’s home page and click the link near the top of the middle column...
-
K3
at least 5% of each type of table with fixed seats have accessible locations with knee space at least 27 inches high, at least 19 inches deep, and at least 30 inches wide with a table top...
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
11B-610.2 Bathtub seats
The top of bathtub seats shall be 17 inches (432 mm) minimum and 19 inches (483 mm) maximum above the bathroom finish floor....
-
10.3.1(16)
At the top and bottom of each escalator run, at least two contiguous treads shall be level beyond the comb plate before the risers begin to form....
-
1018.7.1 Maximum Running Slope and Segment Length
the running slope of a segment a beach access route is steeper than 1:20 (5%), the maximum length of the segment is specified in Table 1018.7.1, and a resting interval is required at the top...
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps. 3....
-
[F] 907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in enclosed exit stairways, enclosed exit ramps, exterior exit stairs and exterior exit ramps....
-
Plan 6B: 12-Foot Wide Accessible Guest Room
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Transfer shower (section 603.2); • Shower seat (section 610.3...
-
Plan 5B: 13-Foot Wide Accessible Guest Room
The following accessible features are provided in the bathroom: • Comparable vanity counter top space (section 806); • Transfer shower (section 603.2); • Shower seat (section 610.3...
-
Breast Platform [M303.4.1]
Breast Platform [M303.4.1] Recommendation: The final recommendation for the minimum height of the breast platform is 26 inches from the floor to the top of the breast platform....
-
M305.2.3 Height (Section-by-Section Analysis)
of transfer support gripping surfaces to be located 6 inches minimum and 19 inches maximum higher than the top of the associated uncompressed transfer surface during use....
- Inclusion Solutions BigBell™ Alert System
-
5.1 Tell the Doctor and the Staff
Or you could say, “There isn’t a curb cut onto the sidewalk from the accessible parking and I had to roll in the street for a block.”...
-
810.2.2 Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191
Dimensions--Modification to 810.2.2 of Appendix D to 36 CFR Part 1191 Bus boarding and alighting areas shall provide a clear length of 96 inches (2440 mm), measured perpendicular to the curb...
- Access Ohio