The toilet room that is currently designated for people with disabilities is not accessible because the door swings into the single user toilet room and encroaches upon the required clear...
Search Results "Clear Ground Space"
-
Attachment E
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep maneuvering space...
-
TEST NO. 2 – SITE ANALYSIS TEST
In no case shall less than 20 percent of the ground floor dwelling units be on an accessible route and comply with the provisions of Division IV. 3. ...
-
4.1.1(5)(b)
(b) Accessibility is not required to (i) observation galleries used primarily for security purposes; or (ii) in non-occupiable spaces accessed only by ladders, catwalks, crawl spaces, very...
-
1012.2 Recreational Vehicles
Parking spaces and pull-up spaces for recreational vehicles shall be 20 feet (6100 mm) wide minimum....
-
1012.2 Recreational Vehicles
Parking spaces and pull-up spaces for recreational vehicles shall be 20 feet (6100 mm) wide minimum....
-
11B-812.7 Access aisle
Two vehicle spaces or one parking space and one electric vehicle charging space shall be permitted to share a common access aisle....
-
T602.4 Size
Wheelchair spaces shall be 30 inches (760 mm) minimum in width and 48 inches (1220 mm) minimum in length....
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
11B-604.8.1.2 Doors
Doors shall not swing into the clear floor space or clearance required for any fixture....
-
1012.2 Recreational Vehicles
This section requires parking spaces and pull-up spaces for recreational vehicles to be 20 feet wide minimum to accommodate recreational vehicles equipped with a lift....
-
F206.4.5 Tenant Spaces
At least one accessible entrance to each tenancy in a facility shall comply with 404. EXCEPTION: Self-service storage facilities not required to comply with F225.3 shall not be...
-
206.4.5 Tenant Spaces
At least one accessible entrance to each tenancy in a facility shall comply with 404. EXCEPTION: Self-service storage facilities not required to comply with 225.3 shall not be...
-
Integration
Under section 221.2.2, wheelchair spaces must be integrated throughout seating areas....
-
Can you put an EV charger in an existing accessible parking space instead of doing costly upgrades?
RESPONSE: The accessibility provisions in CBC Chapter 11B do not permit a required accessible EVCS to be installed in a required accessible parking space....
- Figure 407.4.1(b) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(e) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(d) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(c) Elevator Car Dimensions – Drawing from the U.S. Access Board
- Figure 407.4.1(a) Elevator Car Dimensions – Drawing from the U.S. Access Board
-
Parking Spaces: ADA Standard Section 502
Section 502 covers the current ADA Standards for accessible parking spaces.
-
Doorways
Comment. In transient lodging facilities, doors and doorways in inaccessible guest rooms are required to be at least 32 inches wide (224.1.2). This specification stems from the...
-
G1
G1. Is there an accessible route, at least 36 inches wide, that connects each sleeping area with other shelter activity areas? Yes No Note: it may narrow to 32 inches...
-
1130A.2 Width
1130A.2 Width. The accessible route into and throughout covered multifamily dwelling units shall be at least 36 inches (914 mm) wide.