[2010 ADA Standards] 1....
Search Results "ADA Standard"
Commonly Searched Documents
-
11B-216.5.1 Parking spaces
-
11B-206.4.3 Entrances from tunnels or elevated walkways
[2010 ADA Standards] 206.4.3 Entrances from Tunnels or Elevated Walkways....
-
C. REMEDIAL ACTION
, including the ADA Standards. 18....
-
ABBREVIATIONS
ABBREVIATIONS ABA Architectural Barriers Act of 1968 ADA Americans with Disabilities Act of 1990 ADAAG ADA Accessibility Guidelines for Buildings and Facilities - Appendix...
-
206.2.5 Restaurants and Cafeterias
Florida requirements may be waived down to the ADA Standards requirements....
-
11B-405.5 Clear width
[2010 ADA Standards] 405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum....
-
11B-405.2 Slope
[2010 ADA Standards] EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such...
-
11B-607.4 Grab bars
[2010 ADA Standards] 607.4 Grab Bars. Grab bars for bathtubs shall comply with 609 and shall be provided in accordance with 607.4.1 or 607.4.2. Exceptions: 1. Reserved....
-
For more information
For more information: Copies of the title III rule, the 2010 Standards, and this Fact Sheet are available in an accessible electronic format on the Internet at http://www.ada.gov....
-
For more information
For more information: Copies of the title II rule, the 2010 Standards, and this fact sheet are available in an accessible electronic format on the Internet at http://www.ada.gov....
-
H15
[ADA Standards § 4.17] Yes No If No, check to see if another toilet room provides a wide accessible toilet stall, note its location for shelter planners, and answer all toilet...
-
Where Required: Site Arrival Points [§206.2.1]
Where Required: Site Arrival Points [§206.2.1] This guide explains scoping and technical requirements for accessible routes in the ADA Standards. ...
-
15(f)
(f) If, after January 26, 1993, HWI constructed an addition (as defined in ADA Standards § 3.4) to an Owned Hotel or Joint Venture Hotel that was originally constructed for first occupancy...
-
Further Guidance
Technical assistance and additional guidance on using the ADA Standards is available from the: U.S....
-
11B-407.2.1.1 Height
[2010 ADA Standards] EXCEPTION: Existing call buttons and existing keypads shall be permitted to be located at 54 inches (1370 mm) maximum above the finish floor, measured to the centerline...
-
11B-407.2.2.1 Visible and audible signals
[2010 ADA Standards] 2. In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-407.4.6.2.1 Size and shape
[2010 ADA Standards] 407.4.6.2.1 Size. Buttons shall be ¾ inch (19 mm) minimum in their smallest dimension....
-
§35.151 New Construction and Alterations
ADAAG is the standard for private buildings and was issued as guidelines by the Architectural and Transportation Barriers Compliance Board (ATBCB) under title III of the ADA....
-
§35.151 New construction and alterations. (Section-by-Section Analysis)
ADAAG is the standard for private buildings and was issued as guidelines by the Architectural and Transportation Barriers Compliance Board (ATBCB) under title III of the ADA....
-
11B-223.1 General
[2010 ADA Standards] 223.1 General....
-
11B-221.2.3 Lines of sight and dispersion
[2010 ADA Standards] 221.2.3 Lines of Sight and Dispersion. Wheelchair spaces shall provide lines of sight complying with 802.2 and shall comply with 221.2.3....
-
"Existing Facility" (Section-by-Section Analysis)
Under the ADA, a facility is initially classified as one of three types: (1) An existing facility; (2) an altered facility; or (3) a newly designed and constructed facility. ...
-
11B-706.1 General
[2010 ADA Standards] 706.1 General. Assistive listening systems required in assembly areas shall comply with 706. Advisory 11B-706.1 General....