A. No, except where the specifications in Requirement 7(2)(b) are used. In that case, while the type of control is not specified, the control must be located as shown in Figure 8 of...
Search Results "Walk-in Bathtub"
-
27.1 Q. Do the Guidelines set any requirements for the type or location of bathtub controls?
-
11B-607.4.2.1 Back wall
shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the rim of the bathtub...
-
11B-607.4.2.1 Back wall
shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the rim of the bathtub...
-
T503.3 Steps at Front Doorways
The walking surface on steps serving the front doorway of non-rail vehicles shall be lighted with 2 foot-candles (22 lux) minimum of illumination when the vehicle doors are open....
-
T302 Walking Surfaces
[See subsections ...]
- Aluminum Flush Top SGF Series Pressure-Locked Grating
-
1015.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
1013.2.1 Glazing
Where the glazing provided does not meet the strength and attachment requirements of Section 1607.8, complying guards shall also be located along glazed sides of open-sided walking surfaces...
-
Parallel Grab Bars
Two parallel grab bars are required on the back wall of bathtubs with seats (607.4.1.1) and without seats (607.4.2.1)....
-
F213.3.6 Bathing Facilities
Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided....
-
213.3.6 Bathing Facilities
Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided....
-
1134A.5, Item 5
Bathtub enclosures. Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
1134A.5, Item 5
Bathtub enclosures. Doors and panels of bathtub enclosures shall be substantially constructed from approved, shatter-resistant materials. Hinged doors shall open outward....
-
213.3.6 Bathing Facilities
Where bathtubs or showers are provided, at least one bathtub complying with 607 or at least one shower complying with 608 shall be provided....
- Figure 607.4.1 Grab Bars for Bathtubs with Permanent Seats – Drawing from the U.S. Access Board
-
11B-213.3.6 Bathing facilities
Where bathtubs or showers are provided, at least one bathtub complying with Section 11B-607 or at least one shower complying with Section 11B-608 shall be provided....
-
11B-213.3.6 Bathing facilities
Where bathtubs or showers are provided, at least one bathtub complying with Section 11B-607 or at least one shower complying with Section 11B-608 shall be provided....
-
11B-809.10.5.3 Controls
Exception: Shower spray units are not required in bathtubs....
-
7. Grab Bars
7. Are there two horizontal grab bars (one high/one low) along the side of the tub that are at least 24" long for stabilization and aid in transfer from a wheelchair to the fixed tub...
-
5. Grab Bar
5. Is there a horizontal grab bar at the foot of the tub (by the controls) that is at least 24" long for stabilization while a person with a disability adjusts the water controls -...
-
6. Grab Bars
6. Is there a horizontal grab bar at the head of the tub that is at least 12" long for stabilization and aid in transfer from a wheelchair to the fixed tub seat - see Figure 34 on...
-
4.20.4 Grab Bars
Grab bars complying with 4.26 shall be provided as shown in Fig. 33 and 34.
-
4.20.4 GRAB BARS
Grab bars complying with 4.26 shall be provided as shown in Fig. 33 and 34.
- Figure 607.4.2 Grab Bars for Bathtubs with Removable In-Tub Seats – Drawing from the U.S. Access Board