1.1.5 A maximum design cross slope for accessible exterior pedestrian paving and ramps of 1.5% (1:67 or about 3/16 in. per ft. [15 mm per m]) is recommended....
Search Results "Track Crossing"
Commonly Searched Documents
-
1.1.5
-
4.7.10 DIAGONAL CURB RAMPS
If diagonal curb ramps are provided at marked crossings, the 48 in (1220 mm) clear space shall be within the markings (see Fig. 15(c) and (d))....
-
Overhead Lifts
The technical criteria do not address overhead lifts that are usually mounted on the ceiling and operate on tracks suspended over the diagnostic equipment because the configuration of the...
-
4.3.7 Slope
Nowhere shall the cross slope of an accessible route exceed 1:50....
-
4.3.7 SLOPE
Nowhere shall the cross slope of an accessible route exceed 1:50....
-
R404.2 Surfaces
Surfaces of clear spaces shall comply with R302.7 and shall have a running slope consistent with the grade of the adjacent pedestrian access route and cross slope of 2 percent maximum....
-
Resting Intervals on Trails
Design Tip The cross slope requirement depends on what material is used....
-
11B-406.5.9 Clear space at diagonal curb ramps
Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1219 mm) minimum clear space within the markings....
-
11B-406.5.9 Clear space at diagonal curb ramps
Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1219 mm) minimum clear space within the markings....
-
11B-406.5.9 Clear space at diagonal curb ramps
Diagonal curb ramps provided at marked crossings shall provide the 48 inches (1219 mm) minimum clear space within the markings....
-
Diagonal Curb Ramps: ADA Standard Section 406.6
Section 406.6 covers the current ADA Standards for diagonal curb ramps.
-
Accessible Sidewalks 3: Pedestrians with Low Vision
Requires the Registered User plan or above. Login!
-
6.2.1 Circulation Routes Constructed at Beaches
Beach access routes shall be provided where circulation routes such as boardwalks, walkways, or dune crossings are constructed along or across developed beach sites to provide pedestrian...
- Figure 505.7.2 Handrail Non-Circular Cross Section – Drawing from the U.S. Access Board
-
F248.2 Minimum Number
Pedestrian access points to a beach include parking facilities that serve beaches, dune crossings, and stairways or ramps leading from boardwalks to the beach....
-
Width [4.7.3] and Surface [4.7.4]
The cross-slope of the curb ramp (2% maximum) must be minimized because it makes wheelchair travel difficult by distributing weight and required force to one side and causing front casters...
-
1.2.1 Walks and other non - ramp surfaces
When overall cross slope for sidewalks is measured according to 1.1.4 a recommended tolerance for cross slope is +0.5%....
-
Flange way gap
For rail projects, no flange way gap can be greater than 2.5" where passenger circulation paths cross tracks at grade (i.e. a street-level pedestrian crossing over streetcar tracks)....
-
11B-406.5.10 Diagonal curb ramps
Diagonal curb ramps with flared sides shall have a segment of curb 24 inches (610 mm) long minimum located on each side of the curb ramp and within the marked crossing....
-
The Perils Of Slope
Requires the Registered User plan or above. Login!
-
11B-403.3 Slope
The cross slope of walking surfaces shall not be steeper than 1:48....
-
11B-403.3 Slope
The cross slope of walking surfaces shall not be steeper than 1:48....
-
Location
Location Pushbutton-integrated APS rely on relative proximity to the crossing location, not on difference in sounds, to clarify which street crossing is being signaled....
-
1018.4 Clear Width
EXCEPTION: At dune crossings, the clear width of beach access routes that are not removable shall be permitted to be reduced to 48 inches (1220 mm) minimum....