Section 222 covers scoping requirements in the current ADA Standards for dressing, fitting, and locker rooms.
Search Results "Toilet Room"
Commonly Searched Documents
-
Dressing, Fitting, and Locker Rooms: ADA Standard Section 222
-
Dressing, Fitting, and Locker Rooms: ADA Standard Section 803
[See subsections ...]
-
11B-809.10.4 Sufficient maneuvering space
Where doors swing into the toilet and bathing or powder rooms required to comply with Section 11B-809.10, a clear maneuvering space of 30 (762 mm) inches by 48 inches (1219 mm) minimum shall...
-
11B-805 Medical care and long-term care facilities
, emergency rooms, post anesthesia recovery rooms/units, dialysis rooms/units, infusion rooms/units, labor/delivery/recovery rooms and observation rooms/units....
-
11B-213.3.1.2 Toilet compartments with urinal compartments
Where both toilet compartments and urinal compartments are provided, at least five percent of toilet compartments, but no fewer than one, shall comply with Section 11B-604.8.1 and at least...
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs....
-
11B-222 Dressing, fitting, and locker rooms
[See subsections ...]
-
11B-803 Dressing, fitting, and locker rooms
[See subsections ...]
-
M7
If the door swings into the room, does the door swing not overlap the required clear floor space for the toilet or lavatory?...
-
Water Closet Location.
of "bathroom as shower room."...
-
4.22.2 Doors
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
4.22.2 DOORS
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
- Michael Graves at TEDMED 2011
-
11B-805.4 Examination, diagnostic and treatment rooms
rooms/units, infusion rooms/units, labor/delivery/recovery rooms and observation rooms/units....
-
§ 38.107 Restrooms
[See subsections ...]
-
11B-604.9.7 Toilet Compartments
Toilet compartments shall comply with Section 11B-604.8....
-
11B-213.3.1 Toilet compartments
Where toilet compartments are provided, at least one toilet compartment shall comply with 604.8.1....
-
H2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
M2
Does the door to the toilet room provide at least 32 inches clear passage width when the door is open 90 degrees? [ADA Standards § 4.13.5] Yes No...
-
11B-216.8.3 Signs at toilet and urinal compartments
Where both toilet compartments and urinal compartments are provided, each individual compartment shall be identified with a sign complying with Sections 11B-703.1 through 11B-703.5....
-
11B-213.3.1.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one toilet...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
4.1.2(7)(d)
(d) Accessible toilet and bathing facilities when not all are accessible....
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....