Search Results "Swing"
- AD Systems’ Door - Swing - Double
-
AD Systems’ Door-Swing - Single
Requires the Premium User plan or above. (Login or upgrade your account!)
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
-
11B-408.3.2.1 Power operation
Swinging doors shall be power-operated and shall comply with ANSI/BHMA A156.19....
- Nana Wall Systems, Inc. Sliding Glass Walls HSW60 Video
-
Duration: ADA Standard Section 408.3.2.2
Section 408.3.2.2 covers the current ADA Standards for the duration of swinging doors on limited-use/limited-application elevator.
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
11B-408.3.2.2 Duration
Power-operated swinging doors shall remain open for 20 seconds minimum when activated....
-
Power Operation: ADA Standard Section 408.3.2.1
Section 408.3.2.1 covers the current ADA Standards for the power operation of swinging doors on limited-use/limited-application elevators.
-
Doors in Series and Gates in Series: ADA Standard Section 404.2.6
Section 404.2.6 covers the current ADA Standards for doors in series and gates in series.
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
- Besam SW100 Low Energy Swing Door Operator
-
AD Systems’ Door-Swing - Double - One Sidelite
Requires the Premium User plan or above. (Login or upgrade your account!)
- Besam PowerSwing Electro-hydraulic Swing Door Operator
-
AD Systems’ Door - Swing - Single - One Sidelite
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Elevator Doors: ADA Standard Section 409.3
Section 409.3 covers the current ADA Standards for the doors of private residence elevators.
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
11B-409.3 Elevator doors
Exception: Doors shall not be required to comply with the maneuvering clearance requirements in Section 11B-404.2.4.1 for approaches to the push side of swinging doors....
-
Operation: ADA Standard Section 407.3.2
Section 407.3.2 covers the current ADA Standards for elevator door operations.
- Besam PowerSwing Electro-hydraulic Swing Door Operator BIM
- Besam SW100 Low Energy Swing Door Operator BIM