A manual fire alarm system and an automatic fire detection system shall be installed in Group R-1 occupancies....
Search Results "Smoke Alarm"
Commonly Searched Documents
-
907.2.8 Group R-1
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
806.3.1 Alarms
806.3.1 Alarms. Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
4.3.11.1(7)
Such pressurization system shall be activated by smoke detectors on each floor located in a manner approved by the appropriate local authority....
-
4.28.3(7)
(7) In general, no place in any room or space required to have a visual signal appliance shall be more than 50 ft (15 m) from the signal (in the horizontal plane). In large rooms and...
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 (1999 or 2002 edition) (incorporated by reference, see "Referenced Standards" in Chapter...
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
702 Fire Alarm Systems
702 Fire Alarm Systems...
-
907.2.6.2 Group I-3
Group I-3 occupancies shall be equipped with a manual and automatic fire alarm system installed for alerting staff....
-
Location: ADA Standard Section 407.4.6.4.2
Section 407.4.6.4.2 covers the current ADA Standards for the location of the emergency controls in elevator cars.
-
11B-407.4.6.4.2 Location
Emergency controls, including the emergency alarm, shall be grouped at the bottom of the panel....
-
Location and Spacing
Provisions for the spacing of visual alarms in hallways and corridors generally require one fixture every 100 feet....
-
806.3.1 Alarms
Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
806.3.1 Alarms
Where emergency warning systems are provided, alarms complying with 702 shall be provided....
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.3, and carbon monoxide alarms, where provided, complying with...
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying with...
-
11B-215.4 Transient lodging
Guest rooms required to comply with Section 11B-224.4 shall provide fire alarms complying with Chapter 9, Section 907.5.2.3.2, and carbon monoxide alarms, where provided, complying with...
- Clarity AL10 Visual Alert System informational Video
-
907.2.1 Group A
A manual fire alarm system shall be installed in accordance with NFPA 72 in Group A occupancies having an occupant load of 300 or more....
-
Landscape Forms Inc. Humo Steel Ashtray
Requires the Premium User plan or above. (Login or upgrade your account!)