Grab bars shall not rotate within their fittings....
Search Results "Side Grab Bar"
Commonly Searched Documents
-
609.6 Fittings
-
11B-609.6 Fittings
Grab bars shall not rotate within their fittings....
- AJW Architectural Products UG30-A Series UG30-A12 12" Concealed Set Screw Flange, 1.5" Diameter Grab Bar - Configuration A
- AJW Architectural Products UG20-A Series UG20-A12 12" Concealed Set Screw Flange, 1.25" Diameter Grab Bar - Configuration A
-
Water Closet Location and Rear Grab Bar
Water Closet Location and Rear Grab Bar....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be provided on the back wall and the side wall opposite the seat. Grab bars shall not be provided above the seat....
- Moen Home Care Glacier 12" Grab Bar
-
(5) Reinforced walls for grab bars
The final Guidelines for bathroom wall reinforcement remains essentially unchanged from the Option One guidelines. The only change made to these guidelines has been to subject powder...
- Moen Home Care Peened 12" Grab Bar
-
11B-607.4.1 Bathtubs with permanent seats
For bathtubs with permanent seats, grab bars shall be provided in accordance with Section 11B-607.4.1....
-
11B-607.4.2 Bathtubs without permanent seats
For bathtubs without permanent seats, grab bars shall comply with Section 11B-607.4.2....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
11B-604.9.4 Grab bars
Grab bars for water closets shall comply with Section 11B-604.5....
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.1.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
11B-609.7 Installation
Grab bars shall be installed in any manner that provides a gripping surface at the specified locations and that does not obstruct the required clear floor space....
-
American Specialties Snap Flange Concealed Mounting Grab Bar 3700-Series 3D Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...
-
607.4.1.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and the other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the...
-
11B-607.4.2.1 Back wall
Two grab bars shall be installed on the back wall, one located in accordance with Section 11B-609.4 and the other located 8 inches (203 mm) minimum and 10 inches (254 mm) maximum above the...
-
607.4.2.1 Back Wall
Two grab bars shall be installed on the back wall, one located in accordance with 609.4 and other located 8 inches (205 mm) minimum and 10 inches (255 mm) maximum above the rim of the bathtub...