The requirements for stair and ramp handrails in this document are for adults....
Search Results "Handrail Fitting"
Commonly Searched Documents
-
11B-505.4 Height
-
803 Dressing, Fitting, and Locker Rooms
[See subsections ...]
-
F222 Dressing, Fitting, and Locker Rooms
[See subsections ...]
-
803 Dressing, Fitting, and Locker Rooms
[See subsections ...]
-
222 Dressing, Fitting, and Locker Rooms
[See subsections ...]
- AJW Architectural Products UG2-Railing UG2X-Y108 108" Concealed Snap Flange, 1.25" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG30-Railing UG30X-Y108 108" Concealed Set Screw Flange, 1.5" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG20-Railing UG20X-Y108 108" Concealed Set Screw Flange, 1.25" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG130-Railing UG130X-Y108 108" Exposed Flange, 1.5" Diameter Grab Bar, Peened Grip - Configuration Y
- AJW Architectural Products UG3-Railing UG3X-Y108 108" Concealed Snap Flange, 1.5" Diameter, Peened Grip - Configuration Y
- AJW Architectural Products UG120-Railing UG120X-Y108 108" Exposed Flange, 1.25" Diameter, Peened Grip - Configuration Y
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. [2010 ADAS] Advisory 505.4 Height. ...
-
11B-505.4 Height
Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. Advisory 11B-505.4 Height....
-
Sections 505.10.2 and 505.10.3
Sections 505.10.2 and 505.10.3 of the 2010 Standards require handrail extensions at both the top and bottom of a flight of stairs....
-
Stairs
Error/Omission: Handrail extensions are not provided at the top and bottom risers....
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
4.1.3(21)
(21) Where dressing and fitting rooms are provided for use by the general public, patients, customers or employees, 5 percent, but never less than one, of dressing rooms for each type of...
-
Handrails, Grab Bars, and Tub and Shower Seats [4.26]
Handrails, Grab Bars, and Tub and Shower Seats [4.26] ADAAG 4.26 provides technical requirements for: handrails at ramps [4.8] and stairs [4.9] grab bars at water closets...
-
Section 4.9.4
• Section 4.9.4 of the 1991 Standards requires handrails at the bottom of stairs to continue to slope for a distance of the width of one tread beyond the bottom riser nosing and to further...
-
R409.10.1 Top and Bottom Extension at Ramps
Ramp handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beyond the top and bottom of ramp runs....
-
R409.10.3 Bottom Extension at Stairways
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance at least equal to one tread depth beyond the last riser nosing....
-
R409.10.2 Top Extension at Stairways
At the top of a stair flight, handrails shall extend horizontally above the landing for 305 mm (1.0 ft) minimum beginning directly above the first riser nosing....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....
-
505.8 Surfaces
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges....