Braille dots shall have a domed or rounded shape and shall comply with Table 11B-703.3.1. The indication of an uppercase letter or letters shall only be used before the first word of...
Search Results "Grade Level Exit"
Commonly Searched Documents
- 
    
  
  11B-703.3.1 Dimensions and capitalization
  
- 
    
  
  1003.2.13.1 General
  Stairways within exit enclosures complying with Sections 1003.2.13.2 and 1005.3.2. 3. Elevators complying with Section 1003.2.13.3. 4. Horizontal exits. 5. Smoke barriers.... 
- 
    
  
  1007.2, Item 4
  Exterior exit stairways complying with Sections 1007.3 and 1026 and serving levels other than the level of exit discharge, and Chapter 11A, Section 1115A, or Chapter 11B, Sections 11B-210... 
- 
    
  
  1009.2, Item 4
  Exterior exit stairways complying with Sections 1009.3 and 1027 and Chapter 11A, Section 1115A, or Chapter 11B, Sections 11B-210 and 11B-504, as applicable and serving levels other than... 
- 
    
  
  4.1.3(9)*
  Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in... 
- 
    
  
  Allowances for Typical Roadway Geometry
  access routes within sidewalks to equal the general grade established for the adjacent street or highway.... 
- Braille Authority of North America (BANA)
- 
    
  
  § 37.42(c)(1)
  (1) Level-entry boarding;... 
- 
    
  
  Floor or Ground Surfaces: ADA Standard Section 405.4
  Section 405.4 covers the current ADA Standards for the floor or ground surfaces of ramps. 
- 
    
  
  Trail Slopes
  In this guidebook, the terms running slope and grade often are used interchangeably.... 
- 
    
  
  Turning Space: ADA Standard Section 1008.4.1
  At least one turning space complying with 304 shall be provided on the same level as play components.... 
- 
    
  
  Location: ADA Standard Section 407.4.7.1.2
  Section 407.4.7.1.2 covers the current ADA Standards for the location of designations and indicators on elevator car control buttons. 
- 
    
  
  11B-1008.4.1 Turning space
  At least one turning space complying with Section 11B-304 shall be provided on the same level as play components.... 
- 
    
  
  Changes in Level [4.5.2]
  Vertical changes in level up to ¼ inch are permitted without treatment along accessible routes. Changes in level ¼ to ½ inch must be beveled with a slope no greater than 1:2.... 
- 
    
  
  2.4.1.1
  The running slope (grade) of an ORAR shall be 1:20 (5 percent) or less for any distance. ... 
- 
    
  
  2.4.1.3
  A grade of up to 1:10 (10 percent) is permitted for up to 30 feet (9 m) of an ORAR.... 
- 
    
  
  ADA & Level Boarding - Existing Freight Operations
  49 CFR §37.42(b) MARCH 9, 2012 
- 
    
  
  Running Slope [1017.7.1]
  Running slope, also referred to as grade, is the lengthwise slope of a trail, parallel to the direction of travel.... 
- 
    
  
  409.4.4 Leveling
  Each car shall automatically stop at a floor landing within a tolerance of ½ inch (13 mm) under rated loading to zero loading conditions. 
- 
    
  
  409.4.4 Leveling
  Each car shall automatically stop at a floor landing within a of 1/2 inch (13 mm) under rated loading to zero loading conditions. 
- Besam SL500 CGL Commercial Glass Entry Door - Fixed Sidelite SS BIM
- 
    
  
  C1-4. Accessible Route Level Changes
  Is the accessible route free of steps and abrupt level changes over 1/2 inch? Note: Level changes between 1/4 inch and 1/2 inch should be beveled. Yes _____ No _____... 