Search Results "Floor-Level Exit Sign"
-
216 and 703 Signs
-
1009.2.1 Elevators required
In buildings where a required accessible floor is four or more stories above or below a level of exit discharge or where an accessible occupiable roof is above a story that is three or more...
-
Leveling: ADA Standard Section 408.4.4
Section 408.4.4 covers the ADA Standards for the self-leveling feature in limited-use/limited-application elevators.
-
Height Above Finish Floor or Ground: ADA Standard Section 703.4.1
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
11B-303.3 Beveled
A change in level of 1/2 inch (13 mm) is permitted to be 1/4 inch (6.4 mm) vertical plus 1/4 inch (6.4 mm) beveled....
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADA Standards] 303.2 Vertical....
-
11B-303.2 Vertical
Changes in level of ¼ inch (6.4 mm) high maximum shall be permitted to be vertical and without edge treatment. [2010 ADA Standards] 303.2 Vertical....
- Ronick Matting Systems BaseMat 300 Entrance Floor Mat
-
407.2.3 Hoistway Signs
407.2.3 Hoistway Signs. Signs at elevator hoistways shall comply with 407.2.3....
-
404.2.4.4 Floor or Ground Surface
404.2.4.4 Floor or Ground Surface. Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
Hoistway Signs: ADA Standard Section 408.2.3
Section 408.2.3: covers the current ADA Standards for limited-use/limited-application elevator hoistway signs.
-
1009.2.1 Elevators required
In buildings where a required accessible floor or occupied roof is four or more stories above or below a level of exit discharge, not less than one required accessible means of egress shall...
- BEA Inc. Pneumatic Push Button Automatic Door Access (Push to Exit)
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
404.2.4.4 Floor or Ground Surface
Floor or ground surface within required maneuvering clearances shall comply with 302. Changes in level are not permitted. EXCEPTIONS: 1....
-
Floor or Ground Surface: ADA Standard Section 802.1.1
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
407.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3....
-
407.2.3 Hoistway Signs
Signs at elevator hoistways shall comply with 407.2.3....
-
Employee Work Areas: ADA Standard Section 203.9
Section 203.9 covers scoping requirements of general exceptions for employee work areas in the most current ADA Standards.
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-303.4 Ramps
Changes in level greater than ½ inch (12.7 mm) high shall be ramped, and shall comply with Section 11B-405 or 11B-406....
-
11B-305.2 Floor or ground surfaces
Floor or ground surfaces of a clear floor or ground space shall comply with Section 11B-302....
-
Figure 11B-407.2.3.1 Floor designation
SECTION TITLE NOTES Figure 11B-407.2.3.1 Floor designation....