Search Results "Fire Door"
Commonly Searched Documents
-
§ 35.150(b)(2)(ii)(K) Shooting facilities with firing positions
-
[F] 907.4.2.2 Height
The height of the manual fire alarm boxes shall be a minimum of 42 inches (1067 mm) and a maximum of 48 inches (1219 mm) measured vertically, from the floor level to the activating handle...
-
1.1.3.2, Item 14.3
Fire alarm devices, equipment and systems in connection with any occupancy....
-
5.1.9 Doors
Where provided, doors shall comply with ABAAS section 404. The door shall not swing into or otherwise obstruct the clear floor or ground space or the turning space required by 5.1.4....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
-
907.2.7 Group M
A manual fire alarm system shall be installed in Group M occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
907.2.6.2 Group I-3
Group I-3 occupancies shall be equipped with a manual and automatic fire alarm system installed for alerting staff....
-
Public and Common Use Areas: ADA Standard Section 215.2
Section 215.2 covers scoping requirements in the current ADA Standards for fire alarm systems in public and common use areas.
-
11B-215 Fire alarm systems and carbon monoxide alarm systems
[2010 ADA Standards] 215 Fire Alarm Systems ETA Editor’s Note The CBC includes carbon monoxide alarm systems. Therefore, the CBC is more inclusive....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Force applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
A4.13.11(1) Hinged doors
(1) Hinged doors: Forced applied perpendicular to the door at the door opener or 30 in (760 mm) from the hinged side, whichever is farther from the hinge....
-
907.2.7.1 Occupant notification
During times that the building is occupied, in lieu of the automatic activation of alarm notification appliances, the manual fire alarm system shall be allowed to activate an alarm signal...
-
809.5.1 Building Fire Alarm System
809.5.1 Building Fire Alarm System....
-
407.3 Elevator Door Requirements
407.3 Elevator Door Requirements. Hoistway and car doors shall comply with 407.3....
-
404.2.2 Double-Leaf Doors and Gates
404.2.2 Double-Leaf Doors and Gates. At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
404.3.7 Revolving Doors, Revolving Gates, and Turnstiles
Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
11B-404.3.4 Doors in series and gates in series
Doors in series and gates in series shall comply with Section 11B-404.2.6....
-
Automatic Doors
1997 or 2002 editions of ANSI/BHMA A156.19 Power-Assist and Low-Energy Power-Operated Doors....
-
Transient Lodging: ADA Standard Section 215.4
Section 215.4 covers scoping requirements in the current ADA Standards for fire alarm systems in transient lodging.