The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
Search Results "Elevator Car Door"
Commonly Searched Documents
-
11B-407.3.3.1 Height
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
11B-407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with raised symbols and Braille as shown in Table 11B-407.4.7.1.3...
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
- Otis Gen2 Elevator
-
Keypads: ADA Standard Section 407.4.7.2
Section 407.4.7.2 covers the current ADA Standards for designations and indicators on elevator keypads.
-
11B-407.4.7 Designations and indicators of car controls
Designations and indicators of car controls shall comply with Section 11B-407.4.7....
-
11B-407.4.7 Designations and indicators of car controls
Designations and indicators of car controls shall comply with Section 11B-407.4.7....
-
11B-407.4.7 Designations and indicators of car controls
Designations and indicators of car controls shall comply with Section 11B-407.4.7....
-
11B-411.2.1.2.4.3 Duration
Elevator assignment characters shall be displayed for a minimum of 5 seconds....
-
Elevator Landings: ADA Standard Section 408.2
Section 408.2 covers the current ADA Standards for limited-use/limited-application elevator landings.
-
Frequency: ADA Standard Section 407.4.8.2.3
Section 407.4.8.2.3 covers the current ADA Standards for the frequency of audible elevator car indicators.
-
11B-411.4.6.1 Location
Controls shall be located within one of the reach ranges specified in Section 11B-308.
-
11B-411.4.7.4 Button spacing
Button spacing shall comply with Section 11B-407.4.7.1.5.
-
11B-407.4.6.2.1 Size and shape
11B-407.4.6.2.1 Size and shape. Buttons shall have square shoulders, be ¾ inch (19.1 mm) minimum in their smallest dimension and be raised 1/8 inch (3.2 mm) plus or minus 1/32 inch...
-
11B-411.4.7.1 Type
Control button type shall comply with Section 11B-407.4.7.1.1.
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right.
-
11B-411.4.8.1 Visible indicators
Visible indicators shall comply with Section 11B-411.4.8.1.
-
11B-407.4.8.1.4 Reserved
In destination-oriented elevators, a display shall be provided in the car with visible indicators to show car destinations....
-
Golf Car Passages: ADA Standard Section 1006.3
Golf car passages shall comply with 1006.3....
-
Door and Gate Hardware: ADA Standard Section 404.2.7
Section 404.2.7 covers the current ADA Standards for door and gate hardware.
-
Can elevator doors close sooner than the minimum opening time specified when users activate door close?
User activation of door close (or automatic operation) cannot reduce the initial opening time of doors (3 seconds minimum) or the minimum door signal timing (based on 1.5/ ft/s travel speed...
-
11B-408.4.8 Emergency communications
Car emergency signaling devices complying with Section 11B-407.4.9 shall be provided....