11B-809.12 Electrical receptacles, controls and switches
-
L. Availability of Electrical Power
Availability of Electrical Power Emergency shelters should have a way to provide a back-up power supply when the electrical service is interrupted....
-
Are the elements of path of travel and accessible routes substantively the same (such as slope, vertical clearance, width of path of travel, etc.)?
EVCS required by CBC Chapter 11B to be accessible must have an accessible route to the facility entrance (see CBC Section 11B-812.5.1) and an accessible route from the vehicle space to the...
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....
-
Verify Electrical
VERIFY ELECTRICAL – remember finish material thicknesses! Heights of all 30 amp or less outlet boxes....
-
11B-812.5.3 Relationship to accessible routes
Vehicle spaces and access aisles shall be designed so that when the vehicle space is occupied the required clear width of adjacent accessible routes is not obstructed....
-
11B-812.5.3 Relationship to accessible routes
Vehicle spaces and access aisles shall be designed so that when the vehicle space is occupied the required clear width of adjacent accessible routes is not obstructed....
-
Vehicle Spaces: ADA Standard Section 502.2
Section 502.2 covers the current ADA Standards for vehicle spaces.
-
ACCESSIBLE ROUTE & PATH OF TRAVEL QUESTIONS:
[See subsections ...]
-
We often see projects of gas station replacing old fuel dispensers with access compliance fuel dispensers (reach range, operable parts, point-of-sale). According to Section 11B-202.4, Exception 10, these projects would be required to comply with accessibility for primary accessible path to inside the convenient store at the gas station, public restrooms, drinking fountains, public telephones, and signs (with 20-percent limit of adjusted construction cost). Is my understanding correct regarding the replacement of old/addition of new fuel dispensers?
RESPONSE: Exception 10 to Section 11B-202.4 is only applicable to the installation of EVCS – the exception does not apply to gasoline filling equipment. However, Section 11B-202.4...
-
There does not seem to be a distinction between different EVCS standards (Level 1, Level 2, DC CHAdeMO, DC CCS, and Tesla). Does the schedule defined in Table 11B-228.3.2.1 make a distinction between the different types of EVSE standards or are that all considered to equivalently be an EVCS?
RESPONSE: The CBC Chapter 11B accessibility requirements for EVCS do not distinguish between the different EVCS standards like those listed. However, building officials may view...
-
12142(c)(2) Exception for historic vehicles
(2) Exception for historic vehicles...
- Automotive Mobility Solutions
-
Can you provide recommended signage for ADA accessible spaces?
RESPONSE: Required identification signs for accessible EVCS vehicle spaces are indicated in CBC Chapter 11B Section 11B-812.8 and required vehicle space surface markings are indicated in...
-
ABBREVIATIONS:
The following abbreviations are used in this document: ADA: Americans with Disabilities Act EV: Electric Vehicle CBC: California Building...
- Mockett PCS74 Dome Grommet with 3 Power
- Mockett PCS54WC Recessed Power/Data Grommet Demonstration
-
Plum Lightpad Dimmer Demo
Requires the Registered User plan or above. Login!
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
11B-308.1.2 Electrical receptacle outlets
Electrical receptacle outlets on branch circuits of 30 amperes or less and communication system receptacles shall comply with Section 11B-308 except the low reach shall be measured to the...
-
12181(11) Vehicle
(11) Vehicle The term "vehicle" does not include a rail passenger car, railroad locomotive, railroad freight car, railroad caboose, or a railroad car described in section 12162 of this...
- Mockett PCS54WC Recessed Power/Data Grommet with Wireless Charging
-
Section 37.71 Acquisition of Accessible Vehicles by Public Entities
This section generally sets out the basic acquisition requirements for a public entity purchasing a new vehicle....