Carpet [4.5.3]
-
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard
3) Where the standard says "Changes in level are not permitted", but no advisory follows the standard, such as 404.2.4.4 floor or ground surfaces at doors: Although the Advisory at 304.2...
-
Leveling: ADA Standard Section 408.4.4
Section 408.4.4 covers the ADA Standards for the self-leveling feature in limited-use/limited-application elevators.
-
11B-503.4 Floor and ground surfaces
Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-503.4 Floor and ground surfaces
Access aisles shall be at the same level as the vehicle pull-up space they serve. Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted....
-
11B-504.4 Tread surface
Changes in level, slopes exceeding 1:48, and detectable warnings shall not be permitted. Exception: Reserved....
- PEMKO 1 3/8" Carpet Separator Threshold No. 1951
- PEMKO 1 3/4" Carpet Separator Threshold No. 236
- PEMKO 2 1/2" Carpet Separator Threshold No. 174
-
11B-240.2.1 Ground level play components
Ground level play components shall be provided in the number and types required by Section 11B-240.2.1....
-
11B-240.2.1 Ground level play components
Ground level play components shall be provided in the number and types required by Section 11B-240.2.1....
-
11B-703.8.14 Rate of change
Where a VMS message can be displayed in its entirety on a single screen, it shall be displayed on a single screen and shall remain motionless on the screen for a minimum 3 seconds or...
-
11B-703.8.14 Rate of change
Where a VMS message can be displayed in its entirety on a single screen, it shall be displayed on a single screen and shall remain motionless on the screen for a minimum 3 seconds or...
-
M303.3 Entry
Where there is a change in level at the entry to wheelchair spaces, the change in level shall comply with M303.3....
-
M303.3 Entry
Where there is a change in level at the entry to a wheelchair space, the change in level shall comply with M303.3....
-
§ 38.125(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
§ 38.95(c)(3) Ramp threshold
Changes in level between 1/4 inch and 1/2 inch shall be beveled with a slope no greater than 1:2....
-
11B-813 Adult changing facilities
Adult changing facilities shall comply with Section 11B-813....
-
404.2.4.4 Floor or Ground Surface
Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2. Changes in level at thresholds complying with 404.2.5 shall be permitted....
-
404.2.4.4 Floor or Ground Surface
Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2....
-
11B-404.2.4.4 Floor or ground surface
Changes in level are not permitted. Exceptions: 1. Slopes not steeper than 1:48 shall be permitted. 2. ...
-
11B-404.2.4.4 Floor or ground surface
Changes in level are not permitted. Exceptions: 1. Slopes not steeper than 1:48 shall be permitted. 2....
-
404.2.4.4 Floor or Ground Surface
Changes in level are not permitted. EXCEPTIONS: 1. Slopes not steeper than 1:48 shall be permitted. 2. Changes in level at thresholds complying with 404.2.5 shall be permitted....
-
11B-813.2.12 Signs
A room identification sign complying with Section 11B-216 shall be provided at entrances to adult changing facilities....