One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. Clear floor or ground space may overlap...
Search Results "Approach Enter Exit"
-
11B-305.6 Approach
-
Forward Approach
Forward Approach Clear floor space is required to the face of the unit; a portion can be provided below the unit where clearance is available for toes/knees....
-
1023.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
1022.9 Stairway identification signs
At the exit discharge level, the sign shall include a raised five pointed star located to the left of the identifying floor level....
-
For People with Disabilities, Which Circulation Paths Are Usable, Available, and Closest?
Exits should be marked by tactile signs that are properly located so they can be readily found by a person who is blind or has low vision from any direction of approach to the exit access...
-
1003.2.13.1 General.
Stairways within exit enclosures complying with Sections 1003.2.13.2 and 1005.3.2. Elevators complying with Section 1003.2.13.3....
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
1009.7 Exterior areas for assisted rescue
Where the exit discharge does not include an accessible route from an exit located on the level of exit discharge to a public way, an exterior area of assisted rescue shall be provided on...
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
11B-606.2 Clear floor space
A clear floor space complying with Section 11B-305, positioned for a forward approach, and knee and toe clearance complying with Section 11B-306 shall be provided. Exceptions: 1....
-
1007.8.2 Exterior exit stairway
Exterior exit stairways that are part of the means of egress for the exterior area for assisted rescue shall provide a clear width of 48 inches (1219 mm) between handrails....
-
1007.2 Continuity and components
Stairways within exit enclosures complying with Sections 1007.3 and 1019.1. Elevators complying with Section 1007.4....
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm).
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm).
-
Clear Floor or Ground Space: ADA Standard Section 805.3
The clear floor space shall be positioned for parallel approach to the side of the bed....
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
Examples include exit-only doors with no operating hardware on the exterior side or separate enter and exit fare gates in transit stations....
-
Approach and Maneuvering Clearance [§305.6 and §305.7]
Approach and Maneuvering Clearance [§305.6 and §305.7] Where the space is obstructed on both sides for more than half the depth, additional clearance is required for maneuvering....
- Figure 404.2.4.1(a) Maneuvering Clearances at Manual Swinging Doors and Gates: Front Approach, Pull Side – Drawing from the U.S. Access Board
-
Clear Floor Space: ADA Standard Section 606.2
Section 606.2 covers the current ADA Standards for clear floor space at lavatories and sinks.
-
4.1.3(9)*
Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in...