(ii) A slope between 1:8 and 1:10 is allowed for a maximum rise of 3 inches. A slope steeper than 1:8 is not allowed.
Search Results "Turning Space"
Commonly Searched Documents
-
4.1.6(3)(a)(ii)
-
4.1.6(3)(a)(i)
(i) A slope between 1:10 and 1:12 is allowed for a maximum rise of 6 inches.
-
3.1.4.1 Width of Non-RV Campsite Vehicle Parking Areas
The width of vehicle parking areas shall be at least 16 feet (4880 mm). Exception 1. Where the width of a vehicle parking area cannot be at least 16 feet (3960 mm) because one or...
-
Dispersion of Wheelchair Seating Areas (Section-By-Section Analysis and Response to Comments)
- Dispersal of wheelchair seating areas in theaters will be required only where there are more than 300 seats, rather than in all cases. Seats with removable armrests (i.e., seats...
-
503.4 Floor and Ground Surfaces
Vehicle pull-up spaces and access aisles serving them shall comply with 302. Access aisles shall be at the same level as the vehicle pull-up space they serve....
-
Electric Vehicle Charging Stations
If provided, accessible spaces at EV charging stations cannot count toward the minimum number of accessible car and van parking spaces required in a parking facility....
-
Meeting ANSI Standard S12.60 Requirements
As a result, noise in an adjacent space can reflect off the deck and bounce back down through the ceiling into an adjoining classroom....
-
M303.2.4 Equipment Clearances (Section-by-Section Analysis)
The MDE NPRM proposed knee and toe clearance for diagnostic equipment used by patients seated in wheelchairs to allow for components in the wheelchair space which the patient could approach...
- STI Stopper® Emergency Station, Push, Turn-to-Reset SS-2001E Fire Alarm
-
TICKETING
The revised regulations include a new eight-part section devoted exclusively to the regulation of ticketing for wheelchair spaces and companion seats....
-
§ 382.21 Aircraft accessibility
(2) Aircraft with 100 or more passenger seats shall have a priority space in the cabin designated for stowage of at least one folding wheelchair; (3) Aircraft with more than one aisle...
-
Scoping [4.1.3(5)]
Under ADAAG, a floor must contain occupiable space in order to be considered a "story."...
-
Raised and Brailled Characters and Pictorial Symbol Signs [4.30.4]
They should be avoided or spaced away from raised text. Braille is read with a light sweeping touch using the pad of the finger, not the tip....
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger loading zone and from the passenger loading zone to a vehicular exit shall provide...
-
11B-812.8.1 Four or fewer
Where four or fewer total EVCS are provided, identification with an International Symbol of Accessibility (ISA) and signs identifying van accessible spaces shall not be required....
-
5.8.2.1 Height of Breast Platform at Time of Measurement
Rationale for the recommendation The shape of the breast platform affects the shape of the knee and toe space....
-
11B-503.5 Vertical clearance
Vehicle pull-up spaces, access aisles serving them, and a vehicular route from an entrance to the passenger drop-off and loading zone and from the passenger drop-off and loading zone to...
-
Additional Clearance: ADA Standard Section 306.2.4
Section 306.2.4 covers the current ADA Standards for additional clearances for toe space.
-
Can handrail extensions wrap or turn?
In alterations where the required extension would project hazardously into circulation paths, they can turn, be shorter, or avoided....
-
Clear Floor Space [4.20.2]
Clear Floor Space [4.20.2] Clear floor space at tubs, which is dimensioned according to the approach, may overlap required turning space within the room....
-
703.4.2 Location
Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall....