A clear floor or ground space complying with 305 shall be provided in the load and unload area adjacent to the transfer device....
Search Results "Transfer Surface Height"
-
1002.6.1 Clear Floor or Ground Space
-
4.21.4 Grab Bars
Grab bars complying with 4.26 shall be provided as shown in Fig. 37.
-
4.21.4 GRAB BARS
Grab bars complying with 4.26 shall be provided as shown in Fig. 37. Figure 37 Grab Bars at Shower Stalls
-
Handrail Clearance and Cross Section [§505.5, §505.7]
Handrail Clearance and Cross Section [§505.5, §505.7] Surface requirements and clearances facilitate a power grip along the length of handrails....
-
T302.3 Openings
Openings in walking surfaces shall not allow the passage of a sphere more than 5/8 inch (16 mm) in diameter....
- GE® 27" Drop-In Electric Range JM250DFBB
-
IV. ACCESSIBLE MEDICAL EQUIPMENT
to radiologic exam surfaces that are not accessible....
-
1008.4.2 Clear Floor or Ground Space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
11B-1008.4.2 Clear floor or ground space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
11B-1008.4.2 Clear floor or ground space
Where play components include a seat or entry point, designs that provide for an unobstructed transfer from a wheelchair or other mobility device are recommended....
-
1008.2.6.1 Accessibility
Ground surfaces shall comply with ASTM F 1951 (incorporated by reference, see "Referenced Standards" in Chapter 1)....
-
10.3.1(19)
Gates which must be pushed open by wheelchair or mobility aid users shall have a smooth continuous surface extending from 2 inches above the floor to 27 inches above the floor....
- Kompan, Inc. Elements Play Structures Ridge ELE500003
- Kompan, Inc. Elements Play Structures Tower ELE400050
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
1013.3 Slope
The slope of the surface of tent pads, tent platforms, and clear ground spaces shall not be steeper than 1:48 in any direction....
-
1133A.4, Item 3
Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components....
-
1133A.4, Item 3
Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components....
-
M304.2.2 Standing Supports
Standing supports shall be provided on two sides of the standing surface and shall comply with M305.3....
-
11B-216.2 Designations
at the door to the space that they serve, but this is inferable from the fact that the requirement for braille is contained within 11B-703.2, as are the requirements pertaining to the height...
-
11B-216.2 Designations
at the door to the space that they serve, but this is inferable from the fact that the requirement for braille is contained within 11B-703.2, as are the requirements pertaining to the height...
-
Allowances for Typical Roadway Geometry
for Typical Roadway Geometry The 1991 ADAAG and 2004 ADA and ABA Accessibility Guidelines specify a maximum running slope of 5 percent and maximum cross slope of 2 percent for walking surfaces...
-
11B-703.5.6 Height from finish floor or ground
11B-703.5.6 Height from finish floor or ground. Visual characters shall be 40 inches (1016 mm) minimum above the finish floor or ground. Exceptions: 1....