2. Each exit door that is required to comply with Section 1013.1, and that leads directly to a grade-level exterior exit by means of a stairway or ramp shall be identified by a...
Search Results "Toilet Room Signage"
Commonly Searched Documents
-
1013.4, Item 2
-
11B-703.2.3 Style
11B-703.2.3 Style. Characters shall be sans serif. Characters shall not be italic, oblique, script,highly decorative, or of other unusual forms.
-
11B-703.7.2.4 Assistive listening systems
11B-703.7.2.4 Assistive listening systems. Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure...
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
1010.1.9.7 Delayed egress locks
... 4. An attempt to egress shall initiate an irreversible process that shall allow such egress in not more than 15 seconds when a physical effort to exit is applied to the egress...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum...
-
1010.1.9.8.1 Delayed egress locking system
The delayed egress locking system shall be installed and operated in accordance with all of the following: … 4. An attempt to egress shall initiate an irreversible process that...
-
11B-307.3 Post-mounted objects
Free-standing objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (686 mm) minimum and 80 inches (2032 mm) maximum...
-
11B-408.2.3 Hoistway signs
Signs at elevator hoistways shall comply with Section 11B-407.2.3.1.
-
11B-703.7.2.4 Assistive listening systems
Assistive listening systems shall be identified by the International Symbol of Access for Hearing Loss complying with Figure 11B-703.7.2.4.
-
11B-703.2.3 Style
Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
-
11B-233.3.1.2.4 Multi-story residential dwelling units in buildings with one or more elevators
At least one powder room or bathroom and kitchen shall be located on the primary entry level....
-
15(e)
(e) Within the timeframe set forth in subparagraph 15(a), HWI shall ensure that each Post-1993 Owned Hotel and Post-1993 Joint Venture Hotel has the required number of rooms for guests with...
-
11B-604.8.1.2 Doors
Toilet compartment doors, including door hardware, shall comply with Section 11B-404 except that if the approach is from the push side of the compartment door, clearance between the door...
-
John Brabyn, Ph.D., Director of Rehabilitation Engineering Research, Center on Low Vision and Blindness (NIDRR), Smith-Kettlewell Eye Research Institute
Role of Alternative Signage Braille signs can help but have to be found before they can be read (slide 56)....
-
404.2.4 Maneuvering Clearances
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
Lavatory & Accessory Layouts
The trash receptacle is preferred to be near the door to allow people to pull the door open with a paper towel and drop it into the receptacle before exiting.
- Seton Custom Sized Braille Signs L2852
- Seton 12" x 6" Custom Edged ADA Signs
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
11B-805.3.1 Wheelchair spaces
Where seating is provided in waiting rooms, at least 5 percent of the seating shall be wheelchair spaces complying with Section 11B-802.1....
-
404.2.4 Maneuvering Clearances
EXCEPTION: Entry doors to hospital patient rooms shall not be required to provide the clearance beyond the latch side of the door....
-
9.2.2(2)
(2) An accessible route complying with 4.3 shall connect all accessible spaces and elements, including telephones, within the unit, sleeping room, or suite....