Hands, numerals, and/or digits shall contrast with the background either light-on-dark or dark-on-light....
Search Results "Shall"
Commonly Searched Documents
-
10.3.1(15)
-
10.4.1(7)
Hands, numerals, and/or digits shall contrast with their background either light-on-dark or dark-on-light....
-
1134A.8, Item 4.3
Doors to the cabinet beneath the lavatory shall be removable or openable to provide the required unobstructed knee and toe space....
-
11B-604.9.5 Flush controls
Flush controls shall be hand operated or automatic....
-
11B-407.2.1 Call controls
Where elevator call buttons or keypads are provided, they shall comply with Sections 11B-407.2.1 and 11B-309.4 _|Operation|_. [2010 ADAS] 407.2.1 Call Controls....
-
703.3.2 Position
Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text....
-
703.3.2 Position
Braille shall be positioned below the corresponding text. If text is multi-lined, braille shall be placed below the entire text....
-
610.2 Bathtub Seats
The top of bathtub seats shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the bathroom finish floor....
-
410.6 Doors and Gates
Platform lifts shall have low-energy power-operated doors or gates complying with 404.3. Doors shall remain open for 20 seconds minimum....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
11B-411.2.3.2 Car designation signs
Car designation signs complying with Sections 11B-703.2 and 11B-703.4.1 shall be provided on both jambs of the hoistway immediately below the floor designation....
-
11B-233.3.1.2.5 Multi-story residential dwelling units in buildings with no elevator
residential dwelling units in buildings on a site and shall comply with the following: The primary entry of the multi-story residential dwelling unit shall be on an accessible...
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
11B-1009.2.7 Operation
The lift shall be capable of unassisted operation from both the deck and water levels....
-
404.2.3 Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
402.2 Speech-Output Enabled
ICT with a display screen shall be speech-output enabled for full and independent use by individuals with vision impairments. EXCEPTIONS: 1....
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
404.2.3 Doorways - Clear Width
Door openings shall provide a clear width of 32 inches (815 mm) minimum....
-
11B-1009.2.7 Operation
The lift shall be capable of unassisted operation from both the deck and water levels....
-
11B-705.2 Detectable directional texture
Detectable directional texture at transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm) , with bars...
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
11B-505.10.3 Bottom extension at stairs
At the bottom of a stair flight, handrails shall extend at the slope of the stair flight for a horizontal distance equal to one tread depth beyond the last riser nosing....
-
11B-404.2.3 Clear width
Door openings shall provide a clear width of 32 inches (813 mm) minimum....
-
11B-707.5.1 User control
Speech shall be capable of being repeated or interrupted. Volume control shall be provided for the speech function....