Search Results "Hinge Side Clearance"
- American Standard Madera 1.28 gpf ADA Toilet with Exposed Manual Flush Valve System Side View
- American Standard Madera 1.6 gpf ADA Toilet with Exposed Manual Flush Valve System Side View
- American Standard Madera 1.28 gpf EverClean Toilet with Exposed Manual Flush Valve System Side View
-
ELKAY Filtered EZH2O® Mechanical Surface Mount with Battery-powered visual monitor LMASMB Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Round Corners Medium Capacity Towel Dispenser & 12 Gallon Waste 234-10 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Bradley Round Corners Medium Capacity Towel Dispenser & 12 Gallon Waste 234-11 Side Elevation
Requires the Premium User plan or above. (Login or upgrade your account!)
-
T504.1 General
Passenger access routes shall provide clearances that are sufficient to permit passengers using wheelchairs to move between wheelchair spaces and doorways that provide accessible boarding...
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
11B-206.2.19 Pedestrian street crossings
The curb ramp (excluding any flared sides) or blended transition shall be contained wholly within the width of the pedestrian street crossing served....
-
11B-809.10.7.2 Location
Water closets shall be located within bathrooms in a manner that permits a grab bar to be installed on at least one side of the fixture....
-
2. Question: What is the minimum width needed for a level boarding railroad passenger station platform to meet the accessibility requirements of the Americans with Disabilities Act (ADA)?
For a conventional level boarding side passenger platform with a railing or a wall on the platform side opposite the track, the minimum platform width should be the sum of the maximum dimensions...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
1008.3.1.3 Transfer Space
The 48 inch (1220 mm) long minimum dimension of the transfer space shall be centered on and parallel to the 24 inch (610 mm) long minimum side of the transfer platform....
-
T213.3 Armrests at Aisle Seats on Over-the-Road Buses
Where armrests are provided on the aisle side of seats on over-the-road buses, folding or removable armrests shall be provided on the aisle side of at least 50 percent of aisle seats....
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
11B-809.10.6.1 Size
with one of the following: A transfer type shower compartment 36 inches (914 mm) wide by 36 inches (914 mm) deep, clear inside dimensions measured at center points of opposing sides...
-
Supporting Documents for the Medical Diagnostic Equipment Accessibility Standards Advisory Committee Report
Subcommittee Report - Mammography Subcommittee Report - Stretchers Subcommittee Report - Weight Scales IDeA Center Memo – Transfer Surface Dimensions IDeA Center Memo - Mammography Knee Clearance...
-
Fixed Seating and Tables
At least 27 inches of knee clearance must be provided between the floor and the underside of the table....
-
M305.3 Standing Supports (Section-by-Section Analysis)
in the MDE NPRM preamble on whether the cross section dimensions for gripping surfaces should be applied to standing supports and whether standing supports can provide a 1½ inch minimum clearance...
-
11B-805.6 Hand washing fixtures, lavatories and sinks
Knee clearance requirement - All accessibility requirements of Section 11B-606 apply to lavatories, sinks and handwashing fixtures required to be accessible. ...
-
11B-805.4.1 Beds, exam tables, procedure tables, gurneys and lounge chairs
A 36 inch (914 mm) minimum wide clear space shall be provided along the full length of each side of beds, exam tables, procedure tables, gurneys and lounge chairs....
-
Accessible Presentation / Speaker’s Platform - Talk Show Style
Side tables should be provided (for water, notes, or other materials) for each guest. Individuals who use wheelchairs or scooters may need a higher side table than other guests....