Where the width of the examination surface is less than 36 inches (915 mm), the clearance depth shall extend the full width of the equipment....
Search Results "Curb Ramp Width"
Commonly Searched Documents
-
M301.4 Lift Compatibility
-
11B-703.2.7 Character spacing
Where characters have rectangular cross sections, spacing between individual raised characters shall be 1/8 inch (3.2 mm) minimum and 4 times the raised character stroke width maximum....
-
11B-812.10.4 Location
EV chargers shall be adjacent to, and within the projected width of, the vehicle space being served. Exceptions: 1....
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors....
-
M302.4.2 Clearance Around Base
The width of the base permitted within this clearance shall be 26 inches (660 mm) wide maximum at the edge of the examination surface and shall be permitted to increase at a rate of 1 inch...
-
M305.2.2.2 Side Transfer Supports
Transfer supports for transfer surfaces complying with M301.2.3.2 shall be 28 inches (710 mm) long minimum and shall be positioned along the width of transfer surfaces....
-
M301.4.2 Clearance Around Base
The width of the base permitted within this clearance shall be 26 inches (660 mm) wide maximum at the edge of the examination surface and shall be permitted to increase at a rate of 1 inch...
-
LULA Elevator Dimensions
The guidelines specify that LULA elevator cars be at least 42 inches wide and 54 inches deep with a door on the narrow end providing at least 32 inches clear width (408.4.1)....
-
MEASUREMENT TECHNIQUE
MEASUREMENT TECHNIQUE The depth and width are measured along the centerlines of the seat, and the height from the floor to the highest point of the transfer surface: The depth...
-
4.9.4(2)
(2) If handrails are not continuous, they shall extend at least 12 in (305 mm) beyond the top riser and at least 12 in (305 mm) plus the width of one tread beyond the bottom riser....
-
§ 38.75(c)
(c) Characters on signs required by paragraphs (a) or (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10,...
-
§ 38.27(c)
(c) Characters on signs required by paragraphs (a) and (b) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10,...
-
§ 38.55(b)
(b) Characters on signs required by paragraph (a) of this section shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...
-
11B-206.7.9 Team or player seating
While the use of platform lifts is allowed, ramps are recommended to provide access to player seating areas serving an area of sport activity. ◼...
-
2. New Construction and Alterations
The City also requires that sidewalks and curb ramps adjacent to newly constructed or altered City buildings be accessible to persons with disabilities....
-
Surfaces (R302.7) (Section-by-Section Analysis)
Surfaces (R302.7) (Section-by-Section Analysis) The proposed technical requirements for surfaces apply to pedestrian access routes, including curb ramps and blended transitions, and accessible...
-
Table 3
three requirements in the proposed guidelines in Table 3 that will have more than minimal impacts on state and local transportation departments: Detectable warning surfaces on curb...
-
Issue 13: Stub poles
In addition, a fire hydrant is between the crosswalk location (and the curb ramp) and the APS. Figure 16: Stub pole was installed to locate APS near the crosswalk....
-
Protruding Objects
Response by [Participant]: The state of California attempted to address that by requiring what are known as detectable warnings, the bumps on the curb ramps, underneath drinking fountains...
-
Step 6 - Develop a Transition Plan
A transition plan must also include a schedule for providing curb ramps giving priority to walkways serving entities covered by the ADA, including state and local government offices and...
-
505 Handrails
Specifications for handrails in section 505 apply to those provided at ramps, stairs, and along walking surfaces....
-
A. Entrances
Entrances: (1) Royal Street Accessible Entrance and Guest Pull-up Space – Defendants will reconstruct the curb and sidewalk to meet 2010 Standards §§ 206.2.1, 209, 402.2, 405, 406, and...
-
Station 1-Physical Characteristics
Width-measured perpendicular to the direction of travel, including the user's body if it extends beyond the device or vehicle....
-
Accessible Route Guidelines
They increase the minimum width for an accessible route from 36 inches to 48 inches....