Such wheelchair spaces shall not reduce the required means of egress width....
Search Results "Clear Width"
Commonly Searched Documents
-
1003.2.13.5.1 Size
-
Transit Shelters (R308.2) (Section-by-Section Analysis)
A clear space (see R404) must be provided entirely within the transit shelter....
- Panda S.85 All Aluminum Slim Profile Lift and Slide System
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
M9
[ADA Standards § 4.19.2] Yes No Notes: 1. 48-inch minimum by 66-inch minimum clear floor space for toilet 2. 48-inch minimum by 30-inch minimum clear floor space...
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
304.3.2 T-Shaped Space
Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction and the base shall be clear of obstructions 24 inches (610 mm) minimum....
-
1133A.7 Knee and toe space
Knee and toe space, when required by Section 1133A, shall comply with Section 1138A.2 and the following: The knee and toe space shall be clear and unobstructed, or removable base cabinets...
- Access Board: Signs
-
1134A.8, Item 4.1
The space beneath the lavatory shall be left clear and unobstructed;...
-
1011.2.2 Surface
This section requires the surface of the clear ground space to be firm and stable....
-
1134A.8, Item 4.1
The space beneath the lavatory shall be left clear and unobstructed;...
-
5.4.2.2 Transfer and Positioning Support Length Recommendations for Imaging Equipment with Transfer Surfaces
recommendation A transfer support (for transfer surfaces less than or equal to 24” deep) is to extend horizontally along the side of the patient scanning/imaging table at least the minimum width...
-
R306.3.1 Separation
European and Australian roundabouts provide a 610 mm (24 inch) width of tactile surface treatment from the centerline of the curb ramp or blended transition across the full width of the...
-
Station 2-Three-Point Turn
Designers can use this information to select shared use path widths and, if necessary, build wider turnaround areas, so that users can execute U-turns within the confines of the path....
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...
-
Sec.36.304(d)(2)
Such measures include, for example, providing a ramp with a steeper slope or widening a doorway to a narrower width than that mandated by the alterations requirements....
-
M305.2.3 Height
EXCEPTION: Where the width of the transfer surface for imaging beds exceed 24 inches (610 mm), the tops of the gripping surfaces shall be permitted to be 3 inches (75 mm) minimum and 6 inches...
-
Court Sports
Accessible routes must comply with all ADAAG requirements, such as width and changes in level or surface, and must directly connect both sides of the court....
-
704.8.2 First story
The unoccupied space shall be on the same lot or dedicated for public use, shall not be less than 30 feet (9144 mm) in width, and shall have access from a street by a posted fire lane in...
-
407.3.3 Numeric Keys
Some keypads will have a double width zero key and decimal key instead of the asterisk and pound signs found on a telephone keypad. These examples conform to this provision....
-
Built-Up Curb Ramps
Otherwise, consider a wider ramp width (48” min.) so that maneuvering does not occur near drop-offs. ...
-
11B-703.7.2.7 Pedestrian traffic-control buttons
Pole-supported pedestrian traffic-control buttons shall be identified with color coding consisting of a textured horizontal yellow band 2 inches (51 mm) in width encircling the pole, and...