Cars that provide a clear width 51 inches (1295 mm) minimum shall be permitted to provide a clear depth 51 inches (1295 mm) minimum provided that car doors provide a clear opening 36 inches...
Search Results "Building Permit"
Commonly Searched Documents
-
408.4.1 Car Dimensions and Doors
-
1004.1 Clear Floor Space
Clear floor or ground spaces required at exercise machines and equipment shall be permitted to overlap. Advisory 1004.1 Clear Floor Space....
-
407.8.3.2.2 Knee and Toe Space under ICT with Obstructed Forward Reach
Toe space shall be permitted to provide a clear height of 9 inches (230 mm) minimum above the floor and a clear depth of 6 inches (150 mm) maximum from the vertical reference plane toward...
-
221.2.3.1 Horizontal Dispersion
2nd and 3rd quartile of a row is insufficient to accommodate the required number of companion seats and wheelchair spaces, the additional companion seats and wheelchair spaces shall be permitted...
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
505.6 Gripping Surface
Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length...
-
Alterations—28 CFR 35.151
Because HUD cannot use this document to permit the use of a lesser requirement than that required by its Section 504 regulation, HUD is not permitting use of § 35.151(b)....
-
11B-607.2 Clearance
A lavatory complying with Section 11B-606 shall be permitted at the control end of the clearance....
-
11B-405.7.5 Doorways
Where doorways are located adjacent to a ramp landing, maneuvering clearances required by Sections 11B-404.2.4 and 11B-404.3.2 shall be permitted to overlap the required landing area....
-
11B-607.2 Clearance
A lavatory complying with Section 11B-606 shall be permitted at the control end of the clearance....
-
Welcome and Charge to Participants
you’re going to lose the building....
-
1007.12 Alarms/emergency warning systems/accessibility
ETA Editor's Note Sections from California Building Code Chapter 10 not adopted by Division of the State Architect - Access Compliance (DSA-AC) omitted. ...
-
Vertical Access to Mezzanines
mezzanines where provided, ADAAG has not been clear on whether some form of vertical access is nonetheless required to a mezzanine level where no elevator is provided, such as a one-story building...
-
1007.8 Exterior area for assisted rescue
Where walls or openings are between the area for assisted rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or...
-
1003.2.13.7 Exterior area for assisted rescue
Where walls or openings are between the area for assisted rescue and the interior of the building, the building exterior walls within 10 feet (3048 mm) horizontally of a nonrated wall or...
-
Starting Your Plan with Preparedness
Use the plan template that is part of this toolkit to capture important information and decisions to build your plan....
-
4.28.3* VISUAL ALARMS
If such alarms use electricity from the building as a power source, then they shall be installed on the same system as the audible emergency alarms....
-
4.1.6(4)(a)
Curb ramps and ramps to be constructed on existing sites or in existing buildings or facilities may have slopes and rises as shown in Table 2 if space limitations prohibit the use of a 1...
-
907.5.2.3.4 Groups R-2.1, R-3.1 and R-4
ETA Editor's Note The remainder of California Building Code Chapter 9, is not adopted by the Division of the State Architect - Access Compliance (DSA-AC), and has been omitted....
-
707.5.1 User Control
EXCEPTION: Speech output for any single function shall be permitted to be automatically interrupted when a transaction is selected....
-
11B-406.5.6 Grade breaks
Grade breaks shall not be permitted on the surface of ramp runs and turning spaces. Surface slopes that meet at grade breaks shall be flush....
-
1018.4 Clear Width
EXCEPTION: At dune crossings, the clear width of beach access routes that are not removable shall be permitted to be reduced to 48 inches (1220 mm) minimum....
-
Sec.36.308(a)(2)
(2) If removal of seats is not readily achievable, a public accommodation shall provide, to the extent that it is readily achievable to do so, a portable chair or other means to permit a...
-
F206.7.6 Guest Rooms and Residential Dwelling Units
Platform lifts shall be permitted to connect levels within transient lodging guest rooms required to provide mobility features complying with 806.2 or residential dwelling units required...