Exception: In assembly areas, aisle ramps adjacent to seating and not serving elements required to be on an accessible route shall not be required to comply with Section 11B-405....
Search Results "Permanent Seat"
-
11B-405.1 General
-
903.6 Structural Strength
Allowable stresses shall not be exceeded for materials used when a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener, mounting device, or...
-
1009.2.8 Submerged Depth
The lift shall be designed so that the seat will submerge to a water depth of 18 inches (455 mm) minimum below the stationary water level....
-
Temporary Impairments
Or, if the leg did not heal properly, and resulted in a permanent impairment that significantly restricted walking or other major life activities, s/he would be considered to have a disability...
-
Shelves, Sales and Service Counters, and Check-Out Aisles
If these changes are not readily achievable, businesses may provide a clip board or lap board until more permanent changes can be made....
-
302.2 Carpet
Carpets and permanently affixed mats can significantly increase the amount of force (roll resistance) needed to propel a wheelchair over a surface....
-
I. Definitions
. § 35.151) on Election Day, whether such compliance is achieved through permanent architectural measures or through the use of temporary measures such as those provided for in Paragraph...
-
302.2 Carpet
Carpets and permanently affixed mats can significantly increase the amount of force (roll resistance) needed to propel a wheelchair over a surface....
-
302.2 Carpet
Carpets and permanently affixed mats can significantly increase the amount of force (roll resistance) needed to propel a wheelchair over a surface....
- Bradley Plastic Baby Changing Station
- SafePath EZCurb™ Wheelchair Ramps - Vertical Barrier Removal
-
[2010 ADAS] 105.2.2 ASME
The activation button must be permanently identified with the word "HELP."...
-
[2010 ADAS] 105.2.2 ASME
The activation button must be permanently identified with the word "HELP."...
-
2.1(a)(iii) Substantially Limits
its nature and severity; how long it will last or is expected to last; its permanent or long term impact, or expected impact....
- Pilot Rock WUT and WUTH Picnic Table Using Formed Steel Channel
-
ETA Opinion: ADA Signage at Exit Doors
This comes from an interpretation of the wording in ADAAG §4.1.3(16)(a) which states: "Signs which designate permanent rooms and spaces shall comply with 4.30.1, 4.30.4, 4.30.5 and 4.30.6...
-
11B-1002.5.4 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required amusement ride seat designed for transfer and shall not overlap...
-
§382.87(b)
responding to requests from individuals for accommodations under this subpart, you must comply with FAA and applicable foreign government safety requirements, including those pertaining to exit seating...
-
§ 37.42(e)(1)
(1) Except as provided in paragraph (e)(2) of this paragraph, any obstructions on a platform (mini-high platforms, stairwells, elevator shafts, seats etc.) shall be set at least six feet...
-
11B-607.7 Bathtub enclosures
Enclosures for bathtubs shall not obstruct controls, faucets, shower and spray units or obstruct transfer from wheelchairs onto bathtub seats or into bathtubs....
-
4.6.3 Eyepiece
The eyepiece for the telescope or periscope that is usable from a seated position for viewing each point of interest shall be positioned 43 inches (1090 mm) minimum and 51 inches (1295 mm...
-
Performance Areas
Performance Areas An accessible route must connect stages and other performance areas directly to seating areas where they are directly connected by a circulation path as well as to...
-
§ 35.138(a)(2) Ticket sales
event or series of events shall modify its policies, practices, or procedures to ensure that individuals with disabilities have an equal opportunity to purchase tickets for accessible seating...
-
§ 37.42(e)(1)
(1) Except as provided in paragraph (e)(2) of this paragraph, any obstructions on a platform (mini-high platforms, stairwells, elevator shafts, seats etc.) shall be set at least six feet...