Doors, gates, and side lights adjacent to doors or gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel...
Search Results "Door Leaf"
Commonly Searched Documents
-
11B-404.2.11 Vision lights
-
4.34.6.7* OVENS
For side-opening ovens, the door latch side shall be next to the open counter space, and there shall be a pull-out shelf under the oven extending the full width of the oven and pulling out...
-
1010.1.9.7 Delayed egress locks
A sign shall be provided on the door and shall be located above and within 12 inches (305 mm) of the door exit hardware: 6.1....
-
11B-505.2 Where required
At door landings, handrails are not required when the ramp run is less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-703.7.2.6.1 Men’s toilet and bathing facilities
The triangle symbol shall contrast with the door, either light on a dark background or dark on a light background....
- Door King Inc. 6050 / 6100 Residential and Commercial Swing Gate Operator
-
Thresholds at Doorways [4.13.8]
Thresholds at Doorways [4.13.8] Thresholds complicate wheelchair maneuvering through doors, especially at doors equipped with closers....
- Landscape Forms Inc. Lakeside Bench Collection
-
Turnstiles and Security Gates at Entrances
For example, a store that has an inaccessible turnstile at the entrance but also has an exit door (with no turnstile) located near the cash register may be able to use the exit door as an...
-
A. Exterior Routes
[ADA Stds. 4.1.2(1)] Yes __ No __ N/A __ Comments: _________________________________________ 2. ...the accessible parking space access aisles and the exterior doors to the accessible...
-
Notification Devices: ADA Standard Section 806.3.2
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
Determine Your Evacuation Options When Traveling
If you have a significant hearing loss, do you ask for a room equipped with visual alarms that are connected to the fire alarm system, and other notification devices (for doors and telephones...
-
Entrance
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
106.5.29 Entrance
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
Entrance
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
ENTRANCE
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibule if provided, the entry door or gate, and the hardware...
-
4.13.8* Thresholds at Doorways
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
Entrance
An entrance includes the approach walk, the vertical access leading to the entrance platform, the entrance platform itself, vestibules if provided, the entry door(s) or gate(s), and the...
-
4.13.8* THRESHOLDS AT DOORWAYS
Thresholds at doorways shall not exceed 3/4 in (19 mm) in height for exterior sliding doors or 1/2 in (13 mm) for other types of doors....
-
11B-806.3.2 Notification devices
Visible notification devices shall be provided to alert room occupants of incoming telephone calls and a door knock or bell....
-
Attachment G: Modifications to Newly Constructed Facilities
Attachment G: Modifications to Newly Constructed Facilities
-
4. Pressure Gauge
Many people with disabilities have limitations on the amount of force they can exert to open a door or operate a device that requires pushing or pulling....