This provision was originally designed to persuade employers to hire people with disabilities and open up opportunities....
Search Results "Clear Opening"
Commonly Searched Documents
- Bottom Dollars | A Rooted in Rights Original Documentary
-
Paragraph (a) Operable without vision (Section-by-Section Analysis)
Operable without vision (Section-by-Section Analysis) No substantive comments were received on this paragraph and no changes were made, other than the editorial changes mentioned in the opening...
-
§ 36.303(g)(10)
(10) This section does not require the use of open movie captioning as a means of compliance with paragraph (g) of this section, even if providing closed movie captioning for digital movies...
-
407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (125 mm) nominal and 29 inches (735 mm) nominal above the finish floor....
-
1134A.6, Item 1.1
1.1 The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
-
1134A.6, Item 1.1
The shower stall shall measure at least 42 inches wide by 48 inches deep (1067 mm by 1219 mm) with an entrance opening of at least 36 inches (914 mm); or...
-
Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)
Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991...
-
Accessible Routes on the Playing Surface
When the accessible route is provided on the course, a 1-inch high maximum curb is permitted for an opening of 32 inches minimum where the accessible route extends outside the hole....
-
Grab Bars [4.16.4]
Grab Bars [4.16.4] The back grab bar is most usable from the open side. It must be 36 inches long minimum, installed with one end space a maximum of 6 inches from the side wall....
-
Other Safety tips:
Use the “Peep Hole” in the guestroom door to determine who is on the other side before you open the door. [All hotel staff members have uniforms and name tags....
-
1009.3.3 Area of Refuge
Areas of refuge are not required at stairways serving open parking garages....
-
810.2.2 Dimensions
Bus stop boarding and alighting areas shall provide a clear length of 96 inches (2440 mm) minimum, measured perpendicular to the curb or vehicle roadway edge, and a clear width of 60 inches...
-
12101(b)(1)
(1) to provide a clear and comprehensive national mandate for the elimination of discrimination against individuals with disabilities; Sec. 12101 note: Findings and Purposes of ADA...
-
Paragraph (d) Operable without hearing (Section-by-Section Analysis)
Operable without hearing (Section-by-Section Analysis) No substantive comments were received on this paragraph and no changes were made, other than the editorial changes mentioned in the opening...
-
Paragraph (h) Operable without speech (Section-by-Section Analysis)
Operable without speech (Section-by-Section Analysis) No substantive comments were received on this paragraph and no changes were made, other than the editorial changes mentioned in the opening...
-
810.10 Track Crossings
EXCEPTION: Openings for wheel flanges shall be permitted to be 2 1/2 inches (64 mm) maximum....
-
404.2.8.1 Door Closers and Gate Closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
404.2.8.2 Spring Hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
FAQ: How do I submit a job for the Job Board?
To submit details of a job opening to add to the Job Board, you may either: 1. Click on the "FEEDBACK OR HELP" button that appears on every page of Corada. 2....
-
4.19.5 FAUCETS
Self-closing valves are allowed if the faucet remains open for at least 10 seconds....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
§ 38.101(a)
(a) Any stepwell or doorway with a lift, ramp or bridge plate shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread, ramp, bridge plate, or...
-
11B-810.10 Track crossings
Exception: Openings for wheel flanges shall be permitted to be 2½ inches (64 mm) maximum....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...