Ligature-resistant floor mounted toilet shall be Willoughby Model No....
Search Results "Toilet Room"
Commonly Searched Documents
- Willoughby Industries ASETW1490FM Ligature-Resistant Floor Mounted Blowout Series Water Closet
-
11B-604.5.1 Side wall
A bath station that can be activated by a patient lying on the floor shall be provided at each room containing a patient water closet, bathtub, sitz bath, or shower stall....
-
J. Transfer Space
If there is a lavatory in the accessible stall, is there 42" between the center of the toilet and the near edge of the adjacent lavatory to permit persons with disabilities to transfer onto...
-
Egress Signage
216.4 Means of Egress (from 207.3, 410.7, 410.8) 216.5 Parking (from 208.3) 216.6 Entrances (from 206.4.8) 216.7 Elevators (from 407.5.7) 216.8 Toilet...
-
ASSEMBLY AREA
For the purposes of these requirements, assembly areas include, but are not limited to, classrooms, lecture halls, courtrooms, public meeting rooms, public hearing rooms, legislative chambers...
-
Water Closets [4.16]
Clear floor space requirements at a toilet not located in a stall are different from those for a toilet within a stall....
-
Place of Public Accommodation
(B) Provides guest rooms under conditions and with amenities similar to a hotel, motel, or inn, including the following – 1....
-
Assembly Area
For the purposes of these requirements, assembly areas include, but are not limited to, classrooms, lecture halls, courtrooms, public meeting rooms, public hearing rooms, legislative chambers...
-
11B-308.3.2 Obstructed high reach
[Safe Harbor only applies to existing public telephones and coat hooks at Toilet Rooms.] Exceptions: 1. ...
-
11B-225.3 Self-service storage facilities
Accessible Means of Egress complying with Section 11B-207; Parking Spaces complying with Section 11B-208; and, where provided, other public use or common use elements and facilities such as toilet...
-
Neo-Metro Contour Commercial Toilet 8955 Series Model
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Trailheads
He was not able to use the toilet that the rest of his party could use because it wasn't accessible. The U.S....
-
SLEEPING ACCOMMODATIONS
[DSA-AC] Rooms intended and designed for sleeping....
-
6. Clear floor space
Clear floor space: Adequate space is provided to approach the toilet from a variety of wheelchair transfer positions (i.e. diagonal or side approaches)....
-
R212 Street Furniture (Section-by-Section Analysis)
R212 Street Furniture (Section-by-Section Analysis) Drinking fountains, public toilet facilities, tables, and counters must comply with applicable requirements in the 2004 ADA and ABA...
-
Transient Lodging
A building or facility containing one or more guest room(s) for sleeping that provides accommodations that are primarily short-term in nature....
-
Water closet
Water closet Increased sidewall space adjacent to toilet....
-
4.3.2 Seat Height
4.3.2 Seat Height Seat height is an important dimension for establishing the height of built-in seating, toilet heights, tub heights, shower seat heights and other transfer related surfaces...
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-6897.99
- Bobrick Two-Wall Toilet Compartment Grab Bar Peened B-5897.99
-
F. Grab Bars
Does each accessible toilet have a horizontal grab bar on the wall behind the toilet that is at least 36" long and between 33"-36" above the floor for stabilization and assistance during...
-
Flush Controls [4.16.5]
Flush Controls [4.16.5] Flush valve controls must be mounted no more than 44 inches above the floor on the wide side of the toilet so that they are within reach from the available clear...
-
Section 4.1.3, Accessible Buildings: New Construction (Preamble, Section-by-Section Analysis)
Paragraph 11 requires that toilet facilities comply with § 4.22, which requires one accessible toilet stall (60<″×60<″) in each newly constructed restroom....
-
Section 4.1.3, Accessible Buildings: New Construction (Section-By-Section Analysis and Response to Comments)
Paragraph 11 requires that toilet facilities comply with Sec.4.22, which requires one accessible toilet stall (600A60) in each newly constructed restroom....