transit boarding platforms shall comply with Figure 11B-705.2 and shall be 0.1 inch (2.5 mm) in height that tapers off to 0.04 inch (1.0 mm), with bars raised 0.2 inch (5.1 mm) from the surface...
Search Results "Surface"
Commonly Searched Documents
-
11B-705.2 Detectable directional texture
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
Handrail Extensions
ADAAG does not require handrails on sloped surfaces that have a rise of less than 6 inches or a projection less than 72 inches, or a slope of 1:20 (5%) or less....
-
Transfer Height
Transfer Height The height of the transfer device must be between 14 and 24 inches above the load and unload area surface....
-
Openings [1018.6]
Openings are gaps in the surface of a beach access route....
-
Outdoor Conditions [4.8.8]
Exterior ramps must be designed so that water does not accumulate on the ramp or landing surface. A slope up to 2% is allowed at landings for adequate drainage....
-
APPENDIX C
What was your pain/discomfort value associated with this surface (circle)?...
-
1011.4 Picnic Tables
This section requires picnic tables to comply with the technical requirements for dining surfaces in 902.3 of the Architectural Barriers Act Accessibility Guidelines, which requires the...
-
11B-303.5 Warning curbs
Abrupt changes in level exceeding 4 inches (102 mm) in a vertical dimension between walks, sidewalks or other pedestrian ways and adjacent surfaces or features shall be identified by warning...
-
1133A.4 Countertops
A minimum linear length of 30 inches (762 mm) of countertop shall be provided for a work surface. ...
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
5.1.8 Slope
The slope of the surface of the clear ground space shall not be steeper than 1:48 in any direction....
-
1012.5 Slope
The slope of the surface of parking spaces and pull-up spaces shall not be steeper than 1:48 in any direction....
-
GUARD OR GUARDRAIL
A building component or a system of building components located at or near the open sides of elevated walking surfaces that minimizes the possibility of a fall from the walking surface to...
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
11B-904.3.2 Counter
The counter surface height shall be 38 inches (965 mm) maximum above the finish floor or ground....
-
CURB RAMP
A sloping prepared surface, intended for pedestrian traffic, which provides access between a walk or sidewalk and a surface located above or below an adjacent curb face....
-
Subject testing
A study was designed to investigate a correlation between surface roughness and WBV exposure to WC users in an attempt to determine which surfaces should be considered acceptable....
-
5. Significance and Use
5.1 This practice provides a means for obtaining a quantitative estimate of a surface property defined as roughness using longitudinal profile measuring equipment. 5.1.1 The PRI is portable...
-
609 Grab Bars
Specifications address size, spacing, position, surfaces, fittings, and structural strength....
-
Floor Height [1013.4]
If the tent platform floor is raised above grade, the floor height must be no more than 19 inches when measured from the clear ground space to the tent platform surface....
-
2.7 Tread Obstacles
Where tread obstacles exist on the surface of an ORAR, they shall not exceed 1 inch (25 mm) in height....
-
Story
That portion of a building included between the upper surface of a floor and upper surface of the floor or roof next above....