Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
Search Results "Minimum Dimension"
Commonly Searched Documents
-
11B-411.2.1.4.1.1 Arrangement
-
Sec. 12163. Conformance of accessibility standards. [Section 243]
Accessibility standards included in regulations issued under this subpart shall be consistent with the minimum guidelines issued by the Architectural and Transportation Barriers Compliance...
-
1008.2.5.3.2 Handrail Height
The top of handrail gripping surfaces shall be 20 inches (510 mm) minimum and 28 inches (710 mm) maximum above the ramp surface....
-
903.5 Height
The top of the bench seat surface shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the finish floor or ground....
-
904.5.2 Tray Slides
The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the finish floor or ground....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
4.16.4* Grab Bars
The grab bar behind the water closet shall be 36 in (915 mm) minimum....
-
R302.3.1 Medians and Pedestrian Refuge Islands
The clear width of pedestrian access routes within medians and pedestrian refuge islands shall be 1.5 m (5.0 ft) minimum....
-
9.5.2(2)(d)
(d) at least one common area which a person with mobility impairments can approach, enter and exit including a minimum clear door width of 32 in (815 mm)....
-
609.2.1 Circular Cross Section
Grab bars with circular cross sections shall have an outside diameter of 1 1/4 inches (32 mm) minimum and 2 inches (51 mm) maximum....
-
4.34.6.4(2)
(2) Base cabinets, if provided, shall be removable under the full 30 in (760 mm) minimum frontage of the counter. The finished floor shall extend under the counter to the wall....
-
1011.6 Water Spouts
Water spouts at water hydrants and water utility hook-ups shall be 28 inches (710 mm) minimum and 36 inches (915 mm) maximum above the ground....
-
11B-404.2.6 Doors in series and gates in series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1219 mm) minimum plus the width of doors or gates swinging into the space....
-
11B-411.2.1.4.1.1 Arrangement
Buttons shall be arranged in columns to the right of the keypad with a minimum horizontal spacing of 1.5 times the horizontal spacing between the numeric keys and with the same vertical...
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-607.4.2.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-602.8 Depth
Wall- and post-mounted cantilevered drinking fountains shall be 18 inches (457 mm) minimum and 19 inches (483 mm) maximum in depth....
-
11B-607.4.1.2 Control end wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.2.3 Head end wall
A grab bar 12 inches (305 mm) long minimum shall be installed on the head end wall at the front edge of the bathtub....
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-304.3.1 Circular space
The turning space shall be a space of 60 inches (1524 mm) diameter minimum. The space shall be permitted to include knee and toe clearance complying with Section 11B-306....