When the NYS standards were drafted in l988‒89, the manufacturers could not reach a consensus regarding minimum energy level of the IR light at a set distance from the emitters....
Search Results "Minimum Dimension"
-
2.3.1 Standards
-
Prohibited Reduction in Access
Reductions in access are allowed only where, and to the extent that, the minimum level required in new construction is exceeded....
-
11B-602.9 Pedestrian protection
The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7....
-
IV.B.2.
Characters on signs required by paragraph IV.B.1 of this appendix shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
1009.2.9 Lifting Capacity
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
-
Question 4
Is the full width (minimum 3 feet) of the entire accessible route up to the business entrance clear of obstacles?...
-
5.8.2.4 Unobstructed Floor Space
The unobstructed floor space in front of the base support should be a minimum of 17 inches deep....
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers
The base of the equipment must provide a clearance of 39 inches wide minimum....
-
T503.2 Ramps and Bridgeplates
When ramps or bridgeplates are deployed, the walking surface shall be lighted with 2 foot-candles (22 lux) minimum of illumination....
-
1132A.3, Item 6
The width of any component in the means of egress system shall not be less than the minimum width required by Section 1005....
-
1134A.7, Item 3
The minimum height of water closet seats shall be 15 inches (381 mm) above the floor....
-
1133A.7, Item 2
The knee and toe space shall be 30 inches (762 mm) wide minimum, centered on the sink, countertop or appliance....
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm) wide minimum where the depth exceeds 24 inches (610 mm)....
-
305.7.2 Parallel Approach
Alcoves shall be 60 inches (1525 mm) wide minimum where the depth exceeds 15 inches (380 mm)....
-
4.3.11.3* Stairway Width
Each stairway adjacent to an area of rescue assistance shall have a minimum clear width of 48 inches between handrails....
-
4.8.4(3)
(3) If ramps change direction at landings, the minimum landing size shall be 60 in by 60 in (1525 mm by 1525 mm)....
-
6.8.1 Size
The resting interval length shall be a minimum of 60 inches (1525 mm) long by 60 inches (1525 mm) wide....
-
505.5 Clearance
Clearance between handrail gripping surfaces and adjacent surfaces shall be 1 1/2 inches (38 mm) minimum....
-
305.7.1 Forward Approach
Alcoves shall be 36 inches (915 mm)wide minimum where the depth exceeds 24 inches (610 mm)....