mm) high minimum, or barrier shall be provided that prevents the passage of a 4 inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor...
Search Results "Ceramic Tile Flooring"
Commonly Searched Documents
-
11B-405.9.2 Curb or barrier
-
407.4.7.1.3 Symbols
The control button for the emergency stop, alarm, door open, door close, main entry floor, and phone, shall be identified with tactile symbols as shown in Table 407.4.7.1.3....
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
404.2.11 Vision Lights
gates, containing one or more glazing panels that permit viewing through the panels shall have the bottom of at least one glazed panel located 43 inches (1090 mm) maximum above the finish floor...
-
Who Will Provide the Assistance?
Specific Person(s) in the Office or the Building Friend or co-worker Relative Supervisor Building staff Floor safety warden...
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
M1
.), is a sign with raised characters and Braille mounted on the wall adjacent to the latch side of the door and centered 60 inches above the floor?...
-
4.6.1 General
In alterations, where a condition for exception in section 1.1 prohibits full compliance with a specific requirement for clear floor or ground space surface, slope, size, or location, the...
-
604.4 Seats
The seat height of a water closet above the finish floor shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum measured to the top of the seat....
-
§ 38.159(b)(7) Platform gaps
When the platform is at vehicle floor height with the inner barrier (if applicable) down or retracted, gaps between the forward lift platform edge and the vehicle floor shall not exceed...
-
11B-803.5 Coat hooks and shelves
Shelves shall be 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor or ground....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-703.5.5 Character height
Exception: Where provided, floor plans providing emergency procedures information in accordance with Title 19 shall not be required to comply with Section 11B-703.5.5....
-
11B-608.6 Shower spray unit and water
One shower head shall be located at a height of 48 inches (1219 mm) maximum above the shower finish floor....
-
11B-809.10.2 Number of complying bathing rooms and fixtures
Within dormitories in housing at a place of education, dormitory floors served by an accessible route and providing only sleeping rooms complying with 11B-809.6, and where bathrooms are...
- Waterless Co. No-Flush Urinal Anza 2005
-
4. Bed transfer space
Bed transfer space: A 30-inch by 48-inch clear floor space facilitates transfer from a wheelchair to the bed....
-
2. Mirrors
Mirrors: If provided, mirrors need to be mounted with the bottom edge of the reflecting surface no higher than 40 inches above the floor....
-
Overhead Track Lifts
Overhead Track Lifts Overhead track lifts include ceiling mounted lifts and lifts mounted on a frame supported from the floor....
-
F. Stairs
Stairs - Are there floors connected only by stairs, not an elevator or ramp? [ADA Stds. 4.1.3(4)] If yes, then......
-
407.4.6.4.1 Height
Emergency control buttons shall have their centerlines 35 inches (890 mm) minimum above the finish floor....
-
5a.
Are the elevator call buttons mounted in an accessible location with the centerlines at 42 inches above the floor? [ADA Stds 4.10.3] Yes _____ No _____...
-
4.32.4* Height of Tables or Counters
The tops of accessible tables and counters shall be from 28 in to 34 in (710 mm to 865 mm) above the finish floor or ground....
-
5d.
Are raised letters and Braille characters used to identify each floor button and each control? [ADA Stds 4.10.12] Yes _____ No _____...