Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
Search Results "Visible Signal (Elevator Landing)"
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
-
11B-810.6.3 Station names
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-810.6.3 Station names
Signs shall be clearly visible and within the sight lines of standing and sitting passengers from within the vehicle on both sides when not obstructed by another vehicle....
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
11B-215.3 Employee work areas
Where employee work areas have audible alarm coverage, the wiring system shall be designed so that visible alarms complying with Chapter 9, Section 907.5.2.3.1 Exception can be integrated...
-
Tread Width
The visible trail surface measured perpendicular to the direction of travel....
-
R305.2.1 Perpendicular Curb Ramps
behind the back of curb and the distance from either end of the bottom grade brake to the back of curb is more than 1.5 m (5.0 ft), detectable warning surfaces shall be placed on the lower landing...
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
-
11B-702.1 General
Fire alarm systems shall have permanently installed audible and visible alarms complying with NFPA 72 and Chapter 9, Sections 907.5.2.1 and 907.5.2.3....
-
2.1.2.3 New York State Standards
Given a 1000 Hz signal at a level equal to the long-time average level of speech, the average value of the magnetic field should be 100 mA/meter +/- 3 dB between 100 to 8000 Hz, with a maximum...
-
1009.3.2 Submerged Depth
Where landings are required by 405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (760 mm) maximum below the stationary water level....
-
11B-809.5.4 Prohibited use
Visible alarm appliances used to indicate residential dwelling unit smoke detection, carbon monoxide detection, or building fire alarm activation shall not be used for any other purpose...
-
706.1 General
For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight....
-
706.1 General
For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight....
-
706.1 General
For example, an FM system may be better than an infrared system in some open-air assemblies since infrared signals are less effective in sunlight....
-
11B-505.2 Where required
At door landings, handrails are not required when the ramp run is less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
11B-405.9.1 Reserved.
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
11B-405.9.1 Reserved.
The floor or ground surface of the ramp run or landing shall extend 12 inches (305 mm) minimum beyond the inside face of a handrail complying with 505....
-
11B-505.2 Where required
At door landings, handrails are not required when the ramp run is less than 6 inches (152 mm) in rise or 72 inches (1829 mm) in length....
-
Accessible Ramp Features
Top landing part of walk 3. Bottom landing part of walk 4. Handrail height 34 to 38 inches 5. Edge protection...
- inLOOP Commercial Use Product Line 3000 Assistive Listening System
-
[F] 907.5.2.3.1 Public and common use areas
Visible alarm notification appliances shall be provided in public use areas and common use areas, including but not limited to: Band rooms Classrooms Corridors...
-
[F] 907.5.2.3.1 Public and common use areas
Visible alarm notification appliances shall be provided in public use areas and common use area, including but not limited to: Band rooms Classrooms Corridors Gymnasiums Lobbies...
-
11B-1009.3.2 Submerged depth
Where landings are required by Section 11B-405.7, at least one landing shall be located 24 inches (610 mm) minimum and 30 inches (762 mm) maximum below the stationary water level....