Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
Search Results "Signage Location"
-
11B-411.2.1.3.2 Touch screen call console arrangement
-
11B-411.2.1.3.2 Touch screen call console arrangement
Where touch screen call consoles are provided, the touch screen shall be located directly above the accessibility function button....
-
11B-411.2.1.3.1 Keypad call console arrangement
Where keypad call consoles are provided, the display screen shall be located directly above the keypad....
-
Section 36.403 Alterations and Path of Travel (Section-by-Section Analysis)
suggestion is expressly rejected by the language of the existing regulation in § 36.403(c)(2), which makes clear that "alterations to windows, hardware, controls, electrical outlets, and signage...
-
Automated Revolving Doors
contact a slow mode (2 RPM) that can be activated automatically or by user activation (manufacturers have recommended a maximum speed of 4 RPM maximum for general use) signage...
-
6.1 Universal Receiver: Recommendations
We have already recommended, above, that venues note the transmitting frequencies of the ALS on their signage....
-
M301.2.2 Transfer Surface Size
The minimum size of the transfer surface is 28 inches wide minimum and 21 inches deep minimum and is located such that the long dimension of 28 inches is be located parallel to the patient...
-
11B-812.5.1 Accessible route to building or facility
EVCS complying with Section 11B-812 that serve a particular building or facility shall be located on an accessible route to an entrance complying with Section 11B-206.4....
-
11B-221.2.1.5 Stadium-style movie theaters
The required wheelchair spaces shall be located on risers or cross-aisles in the stadium section that satisfy at least one of the following criteria: Located within the rear 60 percent...
-
11B-812.5.1 Accessible route to building or facility
EVCS complying with Section 11B-812 that serve a particular building or facility shall be located on an accessible route to an entrance complying with Section 11B-206.4....
-
Limitations
Limitations The study is limited in scope by the following: Ability to generalize findings to trails in other locations with the same surfaces applied....
-
6. Exemption for Program Access Improvements
Exemption for Program Access Improvements The City will be exempted from any obligation to perform a Program Access Improvement at a particular location if: There exist barriers...
-
11B-606.1 General
If soap and towel dispensers are provided, they must be located within the reach ranges specified in 308....
-
11B-604.8.3 Coat hooks and shelves
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308....
-
§ 38.29(f)
(f) For vehicles in excess of 22 feet in length, the minimum interior height along the path from the lift to the securement location shall be 68 inches....
-
5.4.4 Transfer Support Distance from Transfer Surface Recommendations for M301 and M302
NPRM Proposed Provision: M305.2.1 Location....
-
11B-502.3.3 Marking
The words "NO PARKING" shall be painted on the surface within each access aisle in white letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent vehicular...
-
11B-502.3.3 Marking
The words "NO PARKING" shall be painted on the surface within each access aisle in white letters a minimum of 12 inches (305 mm) in height and located to be visible from the adjacent vehicular...
- ClickAndGo Navigation Wayfinding Technology
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
11B-705.1.2.2.2 Parallel curb ramps
Detectable warnings at parallel curb ramps shall be located so the edge nearest the curb is 6 inches (152 mm) minimum and 8 inches (203 mm) maximum from the demarcation line at the face...
-
604.8.3 Coat Hooks and Shelves
Coat hooks shall be located within one of the reach ranges specified in 308....
-
§382.87(c)
results in involuntary active behavior that would result in the person properly being refused transportation under §382.19, and the passenger could be transported safely if seated in another location...
-
607.5 Controls
Controls, other than drain stoppers, shall be located on an end wall....