Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
Search Results "Minimum Dimension"
-
1003.3.2 Boarding Pier Clearances
-
6.1 Deliberative Process
An initial Committee decision was to recommend adjustable height transfer surfaces, and this 17” to 19” range for the minimum height was consistent with the NPRM....
-
1003.3.2 Boarding Pier Clearances
Boarding piers at boat launch ramps shall provide clear pier space 60 inches (1525 mm) wide minimum and shall extend the full length of the boarding pier....
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
11B-802.1.2 Width
A single wheelchair space shall be 36 inches (914 mm) wide minimum. ...
-
1009.2.9 Lifting Capacity
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
Handrails
Handrails Pool stairs must have handrails with a minimum width between the rails of 20 inches and a maximum of 24 inches....
-
T503.5 Exterior Illumination for Boarding and Alighting Areas
Where doorways have steps, the illumination shall be 1 foot-candle (11 lux) minimum for a distance of 3 feet (915 mm) measured beyond the outside edge of the doorway or bottom step tread...
-
D6. Vestibule Clear Floor Space
Minimum alcove depth of 48 inches if both doors open out Minimum alcove depth of 48 inches + door width when door swings into alcove...
-
2.3.1 Standards
When the NYS standards were drafted in l988‒89, the manufacturers could not reach a consensus regarding minimum energy level of the IR light at a set distance from the emitters....
-
Prohibited Reduction in Access
Reductions in access are allowed only where, and to the extent that, the minimum level required in new construction is exceeded....
-
11B-602.9 Pedestrian protection
The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7....
-
IV.B.2.
Characters on signs required by paragraph IV.B.1 of this appendix shall have a width-to-height ratio between 3:5 and 1:1 and a stroke width-to-height ratio between 1:5 and 1:10, with a minimum...
-
11B-609.4 Position of grab bars
Grab bars shall be installed in a horizontal position, 33 inches (838 mm) minimum and 36 inches (914 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
1009.2.9 Lifting Capacity
Single person pool lifts shall have a weight capacity of 300 pounds. (136 kg) minimum and be capable of sustaining a static load of at least one and a half times the rated load....
-
407.2.2.2 Visible Signals
Visible signal fixtures shall be centered at 72 inches (1830 mm) minimum above the finish floor or ground....
-
609.4 Position of Grab Bars
Grab bars shall be installed in a horizontal position, 33 inches (840 mm) minimum and 36 inches (915 mm) maximum above the finish floor measured to the top of the gripping surface, except...
-
606.4 Faucets
Hand-operated metering faucets shall remain open for 10 seconds minimum....
-
M305.2.7 Clearance
Clearance between the transfer support gripping surface and adjacent surfaces or obstructions shall be 1 ½ inches (38 mm) minimum....
-
Question 4
Is the full width (minimum 3 feet) of the entire accessible route up to the business entrance clear of obstacles?...
-
5.8.2.4 Unobstructed Floor Space
The unobstructed floor space in front of the base support should be a minimum of 17 inches deep....
-
5.7.1.1 Lift Compatibility Clearance in Base for Stretchers
The base of the equipment must provide a clearance of 39 inches wide minimum....
-
T503.2 Ramps and Bridgeplates
When ramps or bridgeplates are deployed, the walking surface shall be lighted with 2 foot-candles (22 lux) minimum of illumination....
-
1132A.3, Item 6