Search Results "Ground Surface"
- Kompan, Inc. Play Structures - ELE500003 - Ridge
- Figure 1007.3.2 Golf Club Reach Range Area – Drawing from the U.S. Access Board
-
Kompan, Inc. Play Structures - ELE400050 - Tower
Requires the Premium User plan or above. (Login or upgrade your account!)
-
5.4.5 Transfer Support Position Recommendation for M301 and M302
5.4.5 Transfer Support Position Recommendation for M301 and M302 Description: Transfer support position refers to the placement of the gripping surface within the minimum and maximum...
-
M305.2.3 Height (Section-by-Section Analysis)
Board sought input from the public in question 20 of the MDE NPRM preamble, on whether a transfer support height requirement of 6 inches minimum and 19 inches maximum above the transfer surface...
- Kompan, Inc. M582 - PlayWorks Sand Play Structure
- Magnuson Group UMEA Waste Receptacles
- Landscape Forms Inc. Select Modular Steel Recycling Units
-
Regulatory Impact Analysis.
rooms with in-swinging doors; stairs; elevators; location of accessible routes to stages; accessible attorney areas and witness stands; assistive listening systems; and accessible teeing grounds...
-
Stages.
Department's proposed requirements mandate an accessible (pedestrian) route that connects all accessible elements within the boundary of the golf course and facility, including teeing grounds...
-
M305.2.1 Location (Section-by-Section Analysis)
surface depths of greater than 24 inches....
-
5.4.5 Transfer Support Position for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
The transfer gripping surface should be located within the minimum and maximum heights....
-
d. Unobstructed Transfer
The MDE NPRM proposed that each transfer side provide unobstructed access to the transfer surface, with an exception to permit temporary obstructions as long as they could be repositioned...
-
11B-224.7 Housing at a place of education
and clustered sleeping rooms) or on floors containing accessible sleeping rooms with mobility features shall provide turning spaces that comply with Section 11B-809.2.2 and kitchen work surfaces...
-
1008.2.4.1 Ground Level
1008.2.4.1 Ground Level. At ground level, the clear width of accessible routes shall be 60 inches (1525 mm) minimum. EXCEPTIONS: 1....
-
5.4.1 Transfer Support Location for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
Transfer supports should be required on both sides of the transfer surface and be movable or removable so they can be out of the way during transfer....
-
5.3.1 Permitted Obstructions to Transfer Sides for M301 and M302
provide options to transfer onto the short side and the long side of the surface....
-
5.4.2 Transfer Support Length for Equipment Used in a Supine, Prone, Side-Lying, or Seated Position
The transfer support should be a minimum length of 15 inches positioned so that the transfer support overlaps the minimum depth of the transfer surface by 80%....
- A Wheelchair Rider's Guide to the California Coast
- Pilot Rock Smoker's Cease Fire Ash Receptacle
-
11B-233.3.1.2.6 Public housing facility site impracticality
ETA Editor's Note This section of the 2019 California Building Code was amended by the Division of the State Architect. The requirements in this section were previously found in...
-
1009.4.4 Surface
Surfaces of transfer walls shall not be sharp and shall have rounded edges....
-
1009.5.5 Surface
The surface of the transfer system shall not be sharp and shall have rounded edges....