The 2010 Standards also include revisions to technical or scoping specifications for certain elements that were addressed in the 1991 Standards, i.e., elements for which there already were...
Search Results "Built-In Element"
-
Section 36.304 Removal of Barriers (Section-by-Section Analysis)
-
Outdoor Recreation Access Routes in Viewing Areas [F246.4]
At viewing areas not located along trails, at least one ORAR must connect accessible parking spaces or other arrival points that serve the viewing area with accessible elements, spaces,...
-
R405.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear space, the knee clearance shall be 280 mm (11 in) deep minimum at 230 mm (9 in) above the finish surface, and 205 mm...
-
Can curbs be used to indicate areas with less than 80” of vertical clearance?
For this reason, barriers significantly higher than a curb or riser, such as a guardrail, planter box, bench, parapet wall, or similar elements are recommended....
-
Clearances [§403.5]
The minimum clearance cannot be reduced by any elements, including handrails or protruding objects....
-
Who is Covered by the ADA?
The ADA also requires businesses to remove architectural barriers in existing buildings and make sure that newly built or altered facilities are constructed to be accessible to individuals...
-
2.6
aisles to wheelchair spaces and (d) satisfying applicable dispersion requirements, with respect to any Existing Theater, Modified Theater, Designed Theater, or Future Construction Theater built...
-
The Look of Disability Discrimination
• A trendy new clothes shop is built with steps to its only entrance, the equivalent of a sign telling people who use wheelchairs that they are not welcomed....
-
"Existing Facility" (Section-by-Section Analysis)
If a facility exists, it is an existing facility whether it was built in 1989, 1999, or 2009....
-
Contractual arrangements with private entities. (Section-by-Section Analysis)
Prisons that are built or run by private entities have caused some confusion with regard to requirements under the ADA. ...
-
Television and Videos
The Television Decoder Circuitry Act of 1990 requires that all televisions with screens 13 inches or larger sold after July 1, 1993, have built-in closed caption decoders....
-
[A] BUILDING
Rather, these elements are generally considered to be facilities. See the definition of FACILITY....
-
Sections 4.2 Through 4.35 (Preamble, Section-by-Section Analysis)
• Sections 4.2 Through 4.35 Sections 4.2 through 4.35 contain the technical specifications for elements and spaces required to be accessible by the scoping provisions (sections 4.1 through...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
§8.3 Accessible route
Accessible route means a continuous unobstructed path connecting accessible elements and spaces in a building or facility that complies with the space and reach requirements of applicable...
-
11. Toilet rooms and bathing facilities
Accessible element or space ANSI A117.1 section APPLICATION 11....
-
Section 2. Common use areas
"Common use areas" means rooms, spaces or elements inside or outside of a building that are made available for the use of residents of a building or the guests thereof....
-
Sec.36.402(b)(1)
(1) Alterations include, but are not limited to, remodeling, renovation, rehabilitation, reconstruction, historic restoration, changes or rearrangement in structural parts or elements, and...
-
Note
Please note that this is not an exhaustive list of the elements and spaces required to be accessible per the 2013 California Building Code. ...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...
-
Accessible Route
A continuous unobstructed path connecting all accessible elements and spaces of a building or facility....
-
Note
Please note that this is not an exhaustive list of the elements and spaces required to be accessible per the 2013 California Building Code. ...
-
306.3.3 Minimum Required Depth
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11 inches (280 mm) deep minimum at 9 inches (230 mm) above the finish floor...