List of Subjects for 28 CFR Parts 35 and 36
-
Volume Control Telephones: ADA Standard Section 704.3
Portable and in-line amplifiers can be used with some phones but are not practical at most public phones covered by these requirements....
-
11B-1009.2.1 Pool lift location
Pool lifts shall be located where the water level is 36 inches (914 mm) minimum and 48 inches (1219 mm) maximum. [2010 ADAS] 1009.2.1 Pool Lift Location. ...
-
Side guard protocol
Then the height of the platform was adjusted incrementally in height: higher and lower than the subject’s seat and the maximum transfer heights high/low that were attainable were recorded...
-
11B-411.2.1.2.3 Accessibility function button
Each dot shall have a base diameter of 0.059 inch (1.5 mm) minimum and 0.063 inch (1.6 mm) maximum and a height of 0.025 inch (0.6 mm) minimum and 0.037 inch (0.9 mm) maximum....
-
11B-1009.2.1 Pool lift location
Pool lifts shall be located where the water level is 36 inches (914 mm) minimum and 48 inches (1219 mm) maximum. [2010 ADAS] 1009.2.1 Pool Lift Location....
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-1009.2.4 Seat
The height of the lift seat shall be designed to allow a stop at 17 inches (432 mm) minimum to 19 inches (483 mm) maximum measured from the deck to the top of the seat surface when in the...
-
11B-904.4.2 Forward approach
A portion of the counter surface that is 36 inches (914 mm) long minimum and 34 inches (864 mm) high maximum shall be provided....
-
11B-608.3.2 Standard roll-in type shower compartments
Grab bars shall be installed 6 inches (152 mm) maximum from adjacent walls. [2010 ADA Standards] 608.3.2 Standard Roll-In Type Shower Compartments....
-
Analysis of impact on small entities.
consider five factors: (1) The continued need for the rule; (2) the nature of complaints or comments received concerning the rule from the public; (3) the complexity of the rule; (4) the extent...
-
Analysis of impact on small entities.
consider five factors: (1) The continued need for the rule; (2) the nature of complaints or comments received concerning the rule from the public; (3) the complexity of the rule; (4) the extent...
-
Alterations [§202.3]
How and to what extent the standards apply is determined by the scope of a project and the elements and spaces altered....
-
11B-604.3.2 Overlap
Notice CAN 2-11B, dated 9/9/14, which includes the following interpretation of Subsection 11B-604.3.2: Showers are fixtures including a 30 inch x 60 inch clear receptor with a minimum/maximum...
-
202.4.2 Accessible Features in the Event of Disproportionality
necessary to make the path of travel to the altered area fully accessible is disproportionate to the cost of the overall alteration, the path of travel shall be made accessible to the extent...
-
Alterations to cells. (Section-by-Section Analysis)
In section 232.2 of the 2004 ADAAG, the Access Board deferred one decision to the Attorney General, specifically: "Alterations to cells shall not be required to comply except to the extent...
-
C101.1 Purpose (Section-by-Section Analysis)
This section also emphasizes, moreover, that the proposed guidelines are to be applied to the extent required by regulations issued by the Federal Communications Commission under the Telecommunications...
-
Q. Must employers be familiar with the many diverse types of disabilities to know whether or how to make a reasonable accommodation?
Accommodations must be made on an individual basis, because the nature and extent of a disabling condition and the requirements of the job will vary in each case....
-
§ 37.9(b)
This paragraph applies only to alterations of individual elements and spaces and only to the extent that provisions covering those elements or spaces are contained in UFAS or ANSI A117.1...
-
11B-604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1524 mm) minimum and a width of 35 inches (889 mm) minimum and 37 inches (940 mm) maximum....
-
703.2.8 Line Spacing
Spacing between the baselines of separate lines of raised characters within a message shall be 135 percent minimum and 170 percent maximum of the raised character height....
-
604.8.2.1 Size
Ambulatory accessible compartments shall have a depth of 60 inches (1525 mm) minimum and a width of 35 inches (890 mm) minimum and 37 inches (940 mm) maximum....
-
M305.3.2.2 Vertical Position
The height of the lowest end of the gripping surface on vertical standing supports shall be 34 inches (865 mm) minimum and 37 inches (940 mm) maximum above the standing surface....
-
903.3 Size
Benches shall have seats that are 42 inches (1065 mm) long minimum and 20 inches (510 mm) deep minimum and 24 inches (610 mm) deep maximum....