An expansion, extension, or increase in the gross floor area or height of a building or facility....
Search Results "Floor Button"
-
Addition
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
11B-405.9.2 Curb or barrier
A curb or barrier shall be provided that prevents the passage of a 4-inch (102 mm) diameter sphere, where any portion of the sphere is within 4 inches (102 mm) of the finish floor or ground...
-
Clear Width: ADA Standard Section 404.2.3
Section 404.2.3 covers the current ADA Standards for clear width at manual doors, doorways and manual gates that are part of an accessible route.
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
11B-404.2.3 Clear width
There shall be no projections into the required clear opening width lower than 34 inches (864 mm) above the finish floor or ground....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
ADDITION
[DSA-AC] An expansion, extension or increase in the gross floor area or height of a building or facility....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. ...
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: 1. Reserved. 2....
-
11B-407.2.2.3 Audible signals
The audible signal and verbal annunciator shall be 10 dB minimum above ambient, but shall not exceed 80 dB, measured at the hall call button. Exceptions: Reserved. Reserved....
-
11B-704.3 Volume control telephones
Most are operated by pressing a button or key....
-
11B-704.3 Volume control telephones
Most are operated by pressing a button or key....
-
Spout Height: ADA Standard Section 602.4
Section 602.4 covers the current ADA Standards for the spout height of drinking fountains.
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
11B-813.2.1 Adult changing table
Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-813.2.1 Adult changing table
Adult changing tables shall be fixed to the floor or a wall and shall comply with Section 11B-813.2.1....
-
11B-602.4 Spout height
Spout outlets shall be 36 inches (914 mm) maximum above the finish floor or ground....
-
11B-411.4.8.2.1 Signal type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Position of Grab Bars: ADA Standard Section 609.4
Section 609.4 covers the current ADA Standards for the position of grab bars.
-
Location: ADA Standard Section 409.3.2
Section 409.3.2 covers the current ADA Standards for the location of private residence elevator doors.
-
Residential Dwelling Unit Communication Systems: ADA Standard Section 708.4
Communications systems between a residential dwelling unit and a site, building, or floor entrance shall comply with 708.4....
-
11B-809.10.5.2 Reinforcement for grab bars
Where bathtubs are installed without surrounding walls reinforcement shall be provided for floor-mounted grab bars. 2....